CLEANING

Cleaning the interior and exterior

• Wash with warm soapy water and rinse with

wet cloth.

• Wipe with dry cloth.
• Clean gasket frequently.
• Wash shelves with water.
• If unit has dew drops on exterior, wipe away

with dry cloth. This tends to happen in the
rainy season.

Compressor

• A dirty condenser will not let unit cool

efficiently. Clean the condenser every three
months by using a brush or vacuum cleaner.

• Especially, be sure to clean the condensor

before reoperating, after a long period of non-
operation.

Check points after cleaning

• Check again the refrigerator for safety.
• Do not plug the power cord with wet hands.
• Check for noise or unit not getting cold.

Caution

• Unplug the power cord before cleaning.
• Clean the refrigerator periodically.
• Do not use the abrasive cleaners, solvents or

polishing agents on plastic parts. These
cleansers may cause cracking or discoloring.

Drainage

• Take out the bottom grill to empty the tray.
• Clean it at least once in 2days.

(in rainy season, it needs everyday.)

Summary of Contents for TGM-14RV

Page 1: ...w turboairinc com FEATURE CHART Casters are applied to TGM 14CRV model How to install the caster and caster brake Refer to page 3 SHELF BOTTOM GRILL DOOR ASSEMBLY HINGE UNDER CONDENSER FAN CONDENSER A...

Page 2: ...rigerator to make noise Avoid places that are exposed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable fe...

Page 3: ...e caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ROTATION CASTER WITH...

Page 4: ...cuum cleaner Especially be sure to clean the condensor before reoperating after a long period of non operation Check points after cleaning Check again the refrigerator for safety Do not plug the power...

Page 5: ...g it Warning Warranty will be voided if the following is found Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor Multiple uni...

Page 6: ...en the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order This is necessary so ice will not build up on evaporator The door is...

Page 7: ...base holder from the lamp base After the work is done up to this stage the shelves can be adjusted into new position Seprate the lamp from the lamp socket and replace with the new lamp Please turn off...

Page 8: ...r shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or com...

Page 9: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Page 10: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: