background image

4

CLEANING

Cleaning the interior and exterior

• Wash with warm soapy water and rinse with

wet cloth.

• Wipe with dry cloth.
• Clean gasket frequently.
• Wash shelves with water.
• If unit has dew drops on exterior, wipe away

with dry cloth. This tends to happen in the
rainy season.

Compressor

• A dirty condenser will not let unit cool

efficiently. Clean the condenser every three
months by using a brush or vacuum cleaner.

• Especially, be sure to clean the condensor

before reoperating, after a long period of non-
operation.

Check points after cleaning

• Check again the refrigerator for safety.
• Do not plug the power cord with wet hands.
• Check for noise or unit not getting cold.

Caution

• Unplug the power cord before cleaning.
• Clean the refrigerator periodically.
• Do not use the abrasive cleaners, solvents or

polishing agents on plastic parts. These
cleansers may cause cracking or discoloring.

Drainage

• Take out the bottom grill to empty the tray.
• Clean it at least once in 2days.

(in rainy season, it needs everyday.)

Summary of Contents for TGM-22CRV

Page 1: ...HART ADVERTISINC PANEL SHELF BOTTOM GRILL DOOR ASSEMBLY BALLAST EVAPORATOR FAN MOTOR EVAPORATOR FAN BLADE EVAPORATOR DRAIN CAP DRAIN HOSE SUCTION PIPE COVER COMPRESSOR DRAIN PAN HINGE TOP FLUORESCENT...

Page 2: ...to make noise Avoid places that are exposed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to dra...

Page 3: ...e castor in rear side and the castor brakes in front side by using castor wrench 2 Use the castor shims to level the cabinet if necessary by inserting them to stems of the castors ROTATION CASTOR WITH...

Page 4: ...cuum cleaner Especially be sure to clean the condensor before reoperating after a long period of non operation Check points after cleaning Check again the refrigerator for safety Do not plug the power...

Page 5: ...g it Warning Warranty will be voided if the following is found Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor Multiple uni...

Page 6: ...d when the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order This is necessary so ice will not build up on evaporator The door...

Page 7: ...7 HOW TO ADJUST A SHELF POSITION AND REPLACE A LAMP...

Page 8: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Page 9: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Page 10: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...