BEFORE REQUSTING SERVICE

S

N

O

I

T

U

L

O

S

S

E

S

U

A

C

S

M

O

T

P

M

Y

S

Product freezing

Not working
- compressor and 

light not on

Refrigerator not 
cooling well.

Noisy

Moisture on exterior of
cabinet.

Moisture on interior of
cabinet.

Door does not close
correctly.

• Turn temperature control to

normal.

• Rearrange product, due to close

to fan.

• Turn temperature control to

normal.

• Check power by plugging power

cord into another outlet that has
power.

• Remove from heat source.

• Remove hot food and allow to

cool.

• Check position of temperature

control.

• Clean condenser.

• Check the refrigerator door.

• Check the installation and insert

the tray correctly.

• Wipe with dry cloth.

• Wipe with dry cloth.

• Keep door closed as ofen as

possible. Wipe with dry cloth.

• Adjust feet under cooler.

• Level unit.

• Reinsert gasket.

The following points are not malfunctions:
• Water-flowing sound can be heard when the compressor stops.

This is a sound of REFRIGERANT flowing.

• When compressor stops by temperature control, it is not out of order.
• This is necessary so ice will not build up on evaporator.
• The door is warm to touch, due to heater that is installed.

• Only a small amount of product

stored in unit.

• Product on top shelf only freezing.

• Temperature of refrigerator below

35˚F.

• Power or electrical failure.

• When the refrigerator is in sunlight

or near a unit that disperses heat.

• When the refrigerator contatins hot

food or too much food.

• When the temperature control is

not set correctly.

• When condenser coil is dirty.

• When refrigerator door is opened

frequently or left open.

• When the installation floor is weak

or the adjustable feet is set
incorrectly.

• When the back-side of the refriger-

ator is close to the wall.

• When the tray is not on the correct

position.

• High-moisture air can produce

dewdrops during the rainy season.

• When food with steam is stored.

• When door is opened frequently.

• When door has slant.

• When floor is not level.

• When door gasket comes out of

place.

Summary of Contents for TGM-22CRV

Page 1: ...HART ADVERTISINC PANEL SHELF BOTTOM GRILL DOOR ASSEMBLY BALLAST EVAPORATOR FAN MOTOR EVAPORATOR FAN BLADE EVAPORATOR DRAIN CAP DRAIN HOSE SUCTION PIPE COVER COMPRESSOR DRAIN PAN HINGE TOP FLUORESCENT...

Page 2: ...to make noise Avoid places that are exposed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to dra...

Page 3: ...e castor in rear side and the castor brakes in front side by using castor wrench 2 Use the castor shims to level the cabinet if necessary by inserting them to stems of the castors ROTATION CASTOR WITH...

Page 4: ...cuum cleaner Especially be sure to clean the condensor before reoperating after a long period of non operation Check points after cleaning Check again the refrigerator for safety Do not plug the power...

Page 5: ...g it Warning Warranty will be voided if the following is found Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor Multiple uni...

Page 6: ...d when the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order This is necessary so ice will not build up on evaporator The door...

Page 7: ...7 HOW TO ADJUST A SHELF POSITION AND REPLACE A LAMP...

Page 8: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Page 9: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Page 10: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: