background image

4

■ 

Ventilation

- Place the refrigerator under proper ventilation
- Keep the cabinet 4” from rear wall.

■ 

Start-up

- Plug the power cord into the wall outlet.
- The outlet should be only for the refrigerator.
- The temperature controller should be on

normal position.

- If disconnected, shut down, wait 5 minutes

before re-starting it.

■ 

Warning

- It is the responsibility of the purchaser in case

of followings.

• Compressor under low voltage
• Compressor more than 7 feet from plug-in

connection.

• Compressor under unstable voltage
• Compressor not under 115V/60Hz

■ 

Temperature control

- To keep the temperature down : Turn the dial

CW.

- To keep the temperaure up : Turn the dial

CCW.

■ 

Set the shelf

- Assemble the link with support beam.

"A Part"

"B Part"

CAUTION

Summary of Contents for TGM-48R

Page 1: ... operating this unit please read these instructions completely FLOURESCENT LAMP SHELF THERMOSTAT DRAIN PAN CONDENSER FAN COMPRESSOR EVAPORATOR COOLING FAN CONDENSER FLOURESCENT LAMP ADVERTISING PANEL GLASS DOOR DOOR HANDLE BOTTOM GRILL ADJUSTABLE FOOT FEATURE CHART FRONT SIDE ...

Page 2: ... discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to drain the water away with easily Put away heat source from the refrigerator High ambient temperature will make cooling efficiency lower Place the refrigerator in an area with low moisture Splashing water or a high moisture area may cause short circuit and make...

Page 3: ...th water Dewdrops in rainy season wipe it with a dry cloth CLEANING Compressor Condenser should be cleaned every 3 months or as needed unit will not cool properly if dirty Especially be sure to clean the condenser before reoperating after a long period of non operation Caution Unplug the power cord before cleaning Clean the refrigerator periodically Do not use the abrasive cleaners solvents or pol...

Page 4: ...connected shut down wait 5 minutes before re starting it Warning It is the responsibility of the purchaser in case of followings Compressor under low voltage Compressor more than 7 feet from plug in connection Compressor under unstable voltage Compressor not under 115V 60Hz Temperature control To keep the temperature down Turn the dial CW To keep the temperaure up Turn the dial CCW Set the shelf A...

Page 5: ...en the compressor is stopped by defrosting control it is not out of order but defrosting function BEFORE REQUESTING SERVICE Because of the differences between ambient temperature and a quantity of food stored when the temp dial is on the cold position Food would freeze in ambient temperature of below 41 F and the temp dial on the cold position When there is a power connection or failure problem Wh...

Page 6: ... date of original installation but not to exceed five 5 years and three 3 months after shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The for 4 year extended compressor warranty applies only to hermetical...

Page 7: ... alteration neglect abuse misuse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE ONE 1 YEAR WARRANTY AND THE ADDITIONAL FOUR 4 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER...

Page 8: ...and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction d...