Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be free

from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original
installation or 27 months after shipment date from Turbo Air , whichever occurs first.

Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within two (2) year of

original installation or twenty seven (27) months after shipment date from manufacturer, whichever occurs first, shall be 
repaired or replaced as stated below. Turbo Air shall be deemed to have fully complied with its obligation under the foregoing 
warranties by electing either one of the following procedures, at the sole discretion of Turbo Air.

1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect.
2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect.

In addition to the (2) two year warranty stated above, Turbo Air warrants its hermetically and semi-hermetically sealed

compressor to be free from defects in both material and workmanship under normal use and service for a period of three (3)
additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from
manufacturer.

Compressors determined by Turbo Air have been defective within this extended time period will, at Turbo Airʼs option, be either

repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the

compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature
control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera.

The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing

qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below
are the approved lubricants for the Tecumseh compressors.

1 ICI-Emkarate RL 184
2 Emery-2927-A
3 Mobile Artic 22A

Failure to comply with recommended lubricant specification will void the compressor warranty.

2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH-

9 desiccant.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained.

MANUFACTURING COMPANY

TWO YEAR WARRANTY

ADDITIONAL THREE YEAR COMPRESSOR WARRANTY

134A(404A) COMPRESSOR WARRANTY

Summary of Contents for TOM-36DX

Page 1: ...OM 50M Mid Heights TOM 36E TOM 48E TOM 60E Vertical Air Curtain www turboairinc com Turbo Air Speeds up the Pace of Innovation Open Display Merchandiser Installation and Operation Manual Please read t...

Page 2: ...re control Thermometer Placing the product Merchandiser not functioning Merchandiser is warm Lights are not working Condenser coil Location of display Leveling of display 5 OPERATING INSTRUCTIONS 7 6...

Page 3: ...Merchandiser For specific questions not answered on this manual please call Keep this manual in a safe place for your reference Failure to read this manual in its entirety can result in misuse of the...

Page 4: ...2 x 78 8 16 5A 13 2W X 5 562 lbs TOM 60DX 60 x 34 2 x 78 8 16 5A 16 8W X 5 635 lbs Model TOM 36E 36 x 29 5 x 81 2 120V 1Ph 60Hz NT6226GK R 404A Timed off defrost 15A 9 6W X 5 498 lbs TOM 48E 48 x 29...

Page 5: ...the installed unit is in a warm ambient area it may not be as effective Position the Merchandiser at the final location before removing the shipping skid There are four bolts at the bottom of the merc...

Page 6: ...near doorways Confirm there is enough clearance for proper air circulation Operating environment not to exceed 75 F 23 C and 55 humidity Do not load product beyond the edge of the shelf Level the cab...

Page 7: ...is Normal 2 The working temperature is from 37 to 40 3 To lower the temperature adjust the knob towards COLD To raise the temperature adjust the knob towards WARM 4 In case of icing caused by hikes i...

Page 8: ...d mild detergent e Wipe with damp cloth Do not leave soap residue 1 Disconnect the electrical power to the unit 2 Remove the front cover and base cover with screw driver 3 Brush the dirt lint etc from...

Page 9: ...k to see that the breaker hasn t tripped b Check that enough power is BEING supplied to the unit c Check that the power switch is on MERCHANDISER NOT FUNCTIONING a Check the condenser to see if it is...

Page 10: ...10 WIRING DIAGRAM timer...

Page 11: ...r shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or com...

Page 12: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Page 13: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: