SPECIFICATIONS

Model

TOM-40*-**-*

39 x 28 x 78.5

120V/1Ph/60Hz

NT6226GK / CAJ9513Z

R-404A

Timed off defrost

15A

10.8W X 5

512 lbs.

TOM-50*-**-*

50.9 x  28 x 78.5

15A

14.4W X 5

590 lbs.

TOM-40M*-**-*

39 x  28 x 60.5

15A

10.8W X 5

421 lbs.

TOM-50M*-**-*

50.9 x  28 x 60.5

15A

14.4W X 4

463 lbs.

Model

TOM-36DX*-**-*

36 x 34.2 x 78.8

120V/1Ph/60Hz

NT6226GK / CAJ9513Z

R-404A

Timed off defrost

16.5A

9.6W X 5

488 lbs.

TOM-48DX*-**-*

48 x 34.2 x 78.8

16.5A

13.2W X 5

562 lbs.

TOM-60DX*-**-*

60 x 34.2 x 78.8

16.5A

16.8W X 5

635 lbs.

Model

TOM-36E*-**-*

36 x 

29.5 x 81.2

120V/1Ph/60Hz

NT6226GK

R-404A

Timed off defrost

15A

9.6W X 5

498 lbs.

TOM-48E*-**-*

48 x 

29.5 x 81.2

15A

13.2W X 5

573 lbs.

TOM-60E*-**-*

60 x 

29.5 x 81.2

15A

16.8W X 5

648 lbs.

Dimension

(W x D x H) in.

Electricity

Full Load Amperes

Compressor

Refrigerant

Lighting

Defrost

Net Weight

Dimension

(W x D x H) in.

Electricity

Full Load Amperes

Compressor

Refrigerant

Lighting

Defrost

Net Weight

Dimension

(W x D x H) in.

Electricity

Full Load Amperes

Compressor

Refrigerant

Lighting

Defrost

Net Weight

Summary of Contents for TOM-36DX

Page 1: ...OM 50M Mid Heights TOM 36E TOM 48E TOM 60E Vertical Air Curtain www turboairinc com Turbo Air Speeds up the Pace of Innovation Open Display Merchandiser Installation and Operation Manual Please read t...

Page 2: ...re control Thermometer Placing the product Merchandiser not functioning Merchandiser is warm Lights are not working Condenser coil Location of display Leveling of display 5 OPERATING INSTRUCTIONS 7 6...

Page 3: ...Merchandiser For specific questions not answered on this manual please call Keep this manual in a safe place for your reference Failure to read this manual in its entirety can result in misuse of the...

Page 4: ...2 x 78 8 16 5A 13 2W X 5 562 lbs TOM 60DX 60 x 34 2 x 78 8 16 5A 16 8W X 5 635 lbs Model TOM 36E 36 x 29 5 x 81 2 120V 1Ph 60Hz NT6226GK R 404A Timed off defrost 15A 9 6W X 5 498 lbs TOM 48E 48 x 29...

Page 5: ...the installed unit is in a warm ambient area it may not be as effective Position the Merchandiser at the final location before removing the shipping skid There are four bolts at the bottom of the merc...

Page 6: ...near doorways Confirm there is enough clearance for proper air circulation Operating environment not to exceed 75 F 23 C and 55 humidity Do not load product beyond the edge of the shelf Level the cab...

Page 7: ...is Normal 2 The working temperature is from 37 to 40 3 To lower the temperature adjust the knob towards COLD To raise the temperature adjust the knob towards WARM 4 In case of icing caused by hikes i...

Page 8: ...d mild detergent e Wipe with damp cloth Do not leave soap residue 1 Disconnect the electrical power to the unit 2 Remove the front cover and base cover with screw driver 3 Brush the dirt lint etc from...

Page 9: ...k to see that the breaker hasn t tripped b Check that enough power is BEING supplied to the unit c Check that the power switch is on MERCHANDISER NOT FUNCTIONING a Check the condenser to see if it is...

Page 10: ...10 WIRING DIAGRAM timer...

Page 11: ...r shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or com...

Page 12: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Page 13: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: