DESCRIPTION
Model
Dimension (
W
×
D
×
H
)
TOM – 40(B)
26.83×38.99×77.98 in
TOM – 50(B)
26.83×50.39×77.98 in
Electricity 120V/1Ph/60Hz
Total Ampere
16A
16A
Compressor CAJ9513Z
Refrigerant
R-404a
Lighting 30W×5
32W×5
Type of Control
Micro process
Type of Defrosting
Timed off defrost
Weight of Case
507 lbs
573 lbs
INSTALLATION INSTRUCTIONS
INSPECTION FOR DAMAGE
Customer is responsible for checking for damage. First inspect crate as
soon as it arrives. Prior to signing if crate is damaged make sure you note
that on bill of lading.
If after uncrating there is concealed damage and crate was in good condition
you must call Customer Service at Turbo Air. Concealed damage must be
reported within 24 hours of receiving unit. Bill of lading will be requested
faxed to claim department. Pictures may be requested of unit and crating.
3
LOCATION OF OPEN DISPLAY
MERCHANDISER
Display is designed to be in an ambient 75 degrees Fahrenheit (dry
bulb) or colder and 55 percent relative humidity. If unit is installed
in a warm ambient, Display will not cool effectively. Move the
display to the final location before removing shipping skid. Allow 3
inches from back of Display to wall. Condenser is in front of Display.
Do not block inlet.
There are four bolts at bottom of display that secure it to shipping
skid, remove all four.
LEVELING OF OPEN DISPLAY
MERCHANDISER
Four leveling legs are provided for leveling Display. If you do not
wish to use levelers they can be turned inwards.
Bottom frame of unit will be on floor. Use a leveler to make sure
unit is leveled on all four corners.
If unit is not leveled drainage of water will not drain properly.
Leveling legs can be adjusted accordingly
.
4