CHEST FROZEN SHOWCASE
TSD-35CF
CHARACTERISTIC
Parts Name
Picture
Check Method and Criterion
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25
°
c)
Model
Main
Wiring
Auxiliary
Wiring
Normal
2.5
~
2.9
Ω
(Approx.)S
4.1
~
4.7
Ω
(Approx.)S
Compressor
Model :TSD-
35CF
KONOR
GQY70AD
164
WATTS
Abnormal
Open(
∞
Ω
) or Short Circuited ( 0
Ω
)
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25
°
c)
Model
8115PTH7M4R7MC1
Normal
(3.8
Ω~
5.6
Ω
, Max current 18A/180V)
PTC Starter
Model : TSD-
35CF
Abnormal
Open(
∞
Ω
) or Short Circuited ( 0
Ω
)
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25
°
c)
Model
T0296/74/T0296/05,B94-130-74,4TM762PBFZZ-
51(6.3)
Normal
Less than 1
Ω
(Approx.)
Cut temperature:115-
125
℃
;Close temperature:70-52
℃
;
Overload
current
:
27A;UTC(Min action current):3.36A/70
℃
Overload
Protector
Model : TSD-
35CF
Abnormal
Open(
∞
Ω
)
TROUBLE SHOOTING
Thermostat
Repair Procedure
1.
Set Thermo Knob to OFF position, pull & straightened feeler
bulb
2.
Remove Thermostat cover and pull out Thermostat from
Thermo Box
3.
Short the thermostat terminal and check, if compressor
runs.
4.
Replace thermostat
5.
After replacing Thermostat, reverse steps above.
PTC Starter
Repair Procedure
1.
Release Relay Cover Fixing Clip.
2.
Remove Relay Cover.
3.
Remove PTC Starter
4.
Pull out PTC Starter, check if open and compare value of
resistance with given value, if not
5.
Hold receptacle terminal then pull electrical wire from PTC
Starter.
6.
Replaces PTC Starter (change overload protector together),
reverse the steps above.
Overload Protector
Repair Procedure
1.
Check for continuity on overload protector, if open
2.
Pull out Overload Protector.
3.
Hold receptacle terminal then pull electrical wire from
Overload Protector.
4.
Replace overload protector.
Summary of Contents for TSD-27CF
Page 3: ...CHEST FROZEN SHOWCASE TSD 27CF ELEC CIRCUIT TSD 27CF COOLING SYSTEM TSD 27CF...
Page 6: ...CHEST FROZEN SHOWCASE TSD 27CF Exploded View of TSD 27CF...
Page 11: ...CHEST FROZEN SHOWCASE TSD 35CF ELEC CIRCUIT TSD 35CF COOLING SYSTEM TSD 35CF...
Page 14: ...CHEST FROZEN SHOWCASE TSD 35CF Exploded View of TSD 35CF...
Page 22: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF Exploded View of TSD 47CF...
Page 23: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF Exploded View of TSD 60CF...