Cleaning and Maintenance 

11 

Water Tank 

 

It is recommended that this procedure is carried out once a 

week.  Frequency of cleaning the element may be increased 

or decreased depending on the quantity of scale depositing 

on the element. 

 

a. 

To remove the water 

tank, 

take hold of top 

and bottom of rack and 

lift front of rack 

upwards to disengage 

front upper and lower 

hangar studs. 

b.  S

wing the RH side rack 

inwards to allow access 

to the water tank.

 

c.  Remove the water tank 

by lifting the tank off 

its hanger studs.  Clean 

with warm soapy water.  

Rinse thoroughly and 

refit. 

 

Water Tank Element 

 

a.  When wet element 

becomes limed / scaled 

up, remove water tank 

and clean as shown 

previously. 

b.  Refit water tank and 

half fill with white 

vinegar or acetic acid, 

then fill to normal level 

with water.  Switch ‘On’ 

unit, and turn Humidity 

Control to ‘8’.  Operate 

for approximately 30 

minutes. 

c.  When cooled, remove water tank and clean element with a 

damp cloth.  Rinse out water tank and refit to the unit. 

d.  Turn ‘On’ water supply. 

 

Condensation Channel 

 

a.  Below the door is a 

condensation channel 

for collecting door 

condensation run-off.  

This is then fed into a 

condensation drawer. 

b.  Empty condensation 

drawer on a regular 

basis and once a week, 

wipe out condensation 

channel and drawer 

with a damp cloth 

moistened with warm water and a mild detergent solution. 

c.  Dry with a soft dry cloth. 

 

Door 

a.  Wash door with warm water and a mild detergent solution 

using a soft sponge in straight lines up and down inner and 

outer surfaces of door.  Rinse with clean, warm water and 

dry off. 

b.  Dry the door thoroughly with a soft dry cloth. 
c.  Clean door glass with a conventional glass cleaner. 

 

Door Seal 

 

Clean door seal with warm water and a detergent solution using 

a soft sponge when required. 

 

Should the door seal become dirty, it can be removed for a 

more thorough cleaning should this be necessary:- 

a.  To remove 1 piece seal, pull 

seal forward until it pulls out 

of location groove around 

the door. 

b. 

Note the way seal is 

fitted to door, with lip 

facing inwards. 

c.  Check seal for wear and 

damage and replace if 

damaged or worn. 

d.  The seal may be washed in 

a sink, taking care not to cut 

or damage the seal. 

e.  Dry the seal thoroughly with a soft dry cloth before  

re-fitting. 

f.  To refit seal, have seal lip facing into centre of door. 
g.  Press seal into locating groove around door until seal is 

properly located. 

 

 
Lamp Glass - All Cabinets

 

 

The Proofer / Holding 

Cabinets are fitted with 2 

square, flush fitting, halogen 

lamps.  These are fitted on 

the L/H inner side panel, 

behind L/Hand side rack. 

a.  To acces the lamp glass, 

firstly remove the L/Hand 

side rack. 

b.  Wash lamp glass using a 

soft sponge and warm 

water with a detergent 

solution.  Rinse with clean 

warm water. 

e.  Dry lamp glass thoroughly 

with a dry cloth. 

f.  Refit L/Hand side rack. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: 

All  maintenance  operations  should  only  be  carried 

out by a qualified service person. 

 

Controls and mechanical parts should be checked and adjusted 

periodically by a qualified service person. 

It is recommended that the appliance is serviced every 6 months. 

Wet Element 

Water Level Sensor 

Water 

Inlet 

Condensation Channel 

Condensation Drawer 

Pull Seal out of locating channel 

Water Tank 

Summary of Contents for P Series

Page 1: ...234277 15 Installation and Operation Manual P M Series Proofer Holding Cabinets Manual Operation ...

Page 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Page 3: ...ation Installation Requirements Unpacking Location Clearances Electrical Connection Water Connection Positioning of Proofer Holding Cabinet Operation Guide Proofer Holding Cabinet Control Panel Description of Controls Operating in Proof Mode Operating in Hold Mode Cleaning Guidelines Proofer Holding Cabinet Cleaning Periodic Maintenance Reversing the Proofer Holding Cabinet Door P8M P12M Only Reve...

Page 4: ...d answer your question Should you contact your TURBOFAN dealer on any matter concerning this Proofer Holding Cabinet please have the information provided opposite readily available This manual must be kept by the owner for future reference A record of the Date of Purchase Date of Installation and Serial Number of the Proofer Holding Cabinet should be recorded in the area provided below The serial ...

Page 5: ...P N E 60HZ 1 95kW 220 240V 1P N E 50 60HZ 1 90kW 8 18 x 26 460 x 660 Full Size Sheet Pan Capacity 16 18 x 13 460 x 330 Half Size Sheet Pan Capacity 8 600 x 400mm Tray Capacity Optional Kit 12 18 x 26 460 x 660 Full Size Sheet Pan Capacity 24 18 x 13 460 x 330 Half Size Sheet Pan Capacity 12 600 x 400mm Tray Capacity Optional Kit 76mm 3 76mm 3 ...

Page 6: ...ons 4 P10M Proofer Holding Cabinet 110 120V 1P N E 60HZ 1 45kW 220 240V 1P N E 50 60HZ 1 50kW 10 1 1 GN Gastronorm Pan Capacity 10 20 x 12 Hotel Steam Pan Capacity 10 18 x 13 Half Size Sheet Pan Capacity 74mm 27 8 ...

Page 7: ... N E 50 60HZ 1 95kW 230 240V 1P N E 50HZ 1 90kW 8 Full Size Sheet Pan Capacity 16 Half Size Sheet Pan Capacity 8 406 x 736mm 16 x 29 Tray Capacity 457 x 762mm 18 x 30 Tray Rack Set Optional 12 Full Size Sheet Pan Capacity 24 Half Size Sheet Pan Capacity 12 406 x 736mm 16 x 29 Tray Capacity 457 x 762mm 18 x 30 Tray Rack Set Optional 76mm 3 74mm 27 8 ...

Page 8: ... Left hand side 0mm 0 Right hand side 25mm 1 Each Proofer Holding Cabinet should be connected to an adequately protected power supply and an isolation switch mounted adjacent to but not behind the Proofer Holding Cabinet and must be readily accessible to the operator This switch must be clearly marked and readily accessible in case of fire Check that the electricity supply is correct to as shown o...

Page 9: ...water supply to check for water leaks NOTE The Proofer Holding Cabinet can be fitted with an optional Water Filter Kit Part No 234347 For fitting instructions refer to the Instruction Sheet supplied with the Water Filter Kit Correctly locate the Proofer Holding Cabinet into its final operating position and lock the front castors to retain the Proofer Holding Cabinet in it s location Water Connecti...

Page 10: ...tes when Thermostat Heating is turned ON and the elements are cycling ON to maintain set temperature Controls air temperature in the Proofer Holding Cabinet Temperature Range 0 85 C 32 185 F Proofing Range 20 40 C 65 105 F Holding Range 65 85 C 150 185 F Indicator light illuminates when Humidity Control is turned ON and elements are cycling ON to maintain the set humidity Controls the cabinet humi...

Page 11: ...ning Do not set the humidity to high as the product will become sticky and wet on the surface A silky to touch surface on the product is a general recommendation for correct humidity levels Avoid excess humidity levels as this will also create excess condensation in the interior of the cabinet NOTE Butter based product requires much less humidity than breads Ensure that power to the Proofer Holdin...

Page 12: ...oduct from Proofer Holding Cabinet interior using a mild anti bacterial detergent and hot water solution and a soft bristled brush f Dry Proofer Holding Cabinet thoroughly with a soft dry cloth Side Racks P8M P12M a To remove side racks for cleaning take hold of top and bottom of rack and lift front of rack upwards to disengage front upper and lower hangar studs b Swing the rack inwards c Take hol...

Page 13: ...uter surfaces of door Rinse with clean warm water and dry off b Dry the door thoroughly with a soft dry cloth c Clean door glass with a conventional glass cleaner Door Seal Clean door seal with warm water and a detergent solution using a soft sponge when required Should the door seal become dirty it can be removed for a more thorough cleaning should this be necessary a To remove 1 piece seal pull ...

Page 14: ...Service No Humidity Unit is in HOLD mode Low water level in trough No water in trough Humidity set too low Humidity Thermostat faulty Wet Element faulty Switch unit to PROOF mode Humidity is only generat ed in PROOF mode Solenoid or Float Switch faulty Call for service Refer to No Water Supply below Set humidity to higher setting Call for service Call for service No Water Supply Water turned Off a...

Page 15: ...ER SOLENOID HUMIDITY ON INDICATOR WATER TANK ELEMENT 650W 120V 600W 240V WATER TANK THERMOSTAT WATER LEVEL RELAY WATER LEVEL FLOAT SWITCH HEATING ELEMENT P8M P10M P85M8 700W 120V 800W 240V P12M P85M12 1200W 120V 1200W 240V HEATING THERMOSTAT 1 P HEATING CIRCUIT HUMIDITY CIRCUIT P4 4 P2 P3 P1 2 3 1 P4 4 P2 P3 P1 2 3 1 P4 4 P2 P3 P1 2 3 1 OFF PROOF HOLD SWITCH SETTINGS FUNCTION SWITCH FUSE 10A ...

Page 16: ...Top P85 M8 P85 M12 236299 Door Hinge Gasket Bottom P10 018947 Magnet Catch 234570 Door Seal P8 236474 Door Seal P10 234537 Door Seal P12 238584 Door Seal P85 M8 238606 Door Seal P85 M12 233528 Float Switch 234348 Water Solenoid 90 Outlet 240V 234349 Water Solenoid 90 Outlet 120V 025922 Adaptor Brass USA Canada only 021527 Washer Rubber USA Canada only 234216 Castor 75mm Rigid Rubber 234217 Castor ...

Page 17: ... unless otherwise stated Door reversal should only be carried out by a suitably competent person 1 Whilst supporting door unscrew and remove top door pivot bolt and Nord Lock washer from top door hinge assembly and lift the door off the bottom hinge 2 Remove top and bottom hinges and gaskets two screws 3 Remove four cover screws covering alternate hinge holes on RH side of proofer opening Refit co...

Page 18: ......

Reviews: