Installation 

1.  Remove all packaging and transit protection including all 

protective plastic coating from the exterior stainless steel 

panels. 

2.  Check the Proofer / Holding Cabinet and supplied parts for 

damage.  Report any damage immediately to the carrier and 

distributor. 

3.  Check that the following parts have been supplied with your 

Proofer / Holding Cabinet :- 

 

 

Adaptor Brass. 

 

Washer Rubber. 

 

4.  Report any deficiencies to the distributor who supplied the 

appliance. 

5.  Ensure that all the castors are fitted securely. 
6.  Check that the available electrical supply is correct to as shown 

on the Technical Data Plate located on the front right hand side 

panel. 

 

- Refer to ‘Specifications’ section. 

 

 

1.  Position the Proofer / Holding Cabinet in its working position. 
2.  The Proofer / Holding Cabinet should be positioned so that the 

control panel and shelves are easily reachable for loading and 

unloading. 

 

To ensure correct ventilation for the motor and controls, the 

following minimum installation clearances are to be adhered to:- 

Top 

0mm / 0”. 

Rear 

0mm / 0”. 

Left-hand side 

0mm / 0”. 

Right-hand side 

25mm / 1”. 

 

Each Proofer / Holding Cabinet should be connected to an 

adequately protected power supply and an isolation switch mounted 

adjacent to, but not behind the Proofer / Holding Cabinet and must 

be readily accessible to the operator.  This switch must be clearly 

marked and readily accessible in case of fire. 

 

Check that the electricity supply is correct to as shown on the  

Technical Data Plate on the front right hand corner of the Proofer / 

Holding Cabinet side panel. 

 

The Turbofan Proofer / Holding Cabinets are supplied with electrical 

cords fitted .  Ensure that the appliance is fitted with the  

appropriate power cord and plug. 

 

Technical Data Plate - Location 

 

 

Installation shall comply with local electrical, health and safety requirements. 

 

 

It is most important that this Proofer / Holding Cabinet  is installed correctly and that the operation is correct before use. 

 

 

If you have any questions regarding the proper installation and / or operation of this Proofer / Holding Cabinet  , please 

contact your local Turbofan distributor. 

 

 

 

This Proofer / Holding Cabinet  must be earthed/grounded. 
If  the  supply  cord  is  damaged,  it  must  be  replaced  by  a 

suitably qualified person in order to avoid a hazard. 

USA / Canada only. 

Summary of Contents for P Series

Page 1: ...234277 15 Installation and Operation Manual P M Series Proofer Holding Cabinets Manual Operation ...

Page 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Page 3: ...ation Installation Requirements Unpacking Location Clearances Electrical Connection Water Connection Positioning of Proofer Holding Cabinet Operation Guide Proofer Holding Cabinet Control Panel Description of Controls Operating in Proof Mode Operating in Hold Mode Cleaning Guidelines Proofer Holding Cabinet Cleaning Periodic Maintenance Reversing the Proofer Holding Cabinet Door P8M P12M Only Reve...

Page 4: ...d answer your question Should you contact your TURBOFAN dealer on any matter concerning this Proofer Holding Cabinet please have the information provided opposite readily available This manual must be kept by the owner for future reference A record of the Date of Purchase Date of Installation and Serial Number of the Proofer Holding Cabinet should be recorded in the area provided below The serial ...

Page 5: ...P N E 60HZ 1 95kW 220 240V 1P N E 50 60HZ 1 90kW 8 18 x 26 460 x 660 Full Size Sheet Pan Capacity 16 18 x 13 460 x 330 Half Size Sheet Pan Capacity 8 600 x 400mm Tray Capacity Optional Kit 12 18 x 26 460 x 660 Full Size Sheet Pan Capacity 24 18 x 13 460 x 330 Half Size Sheet Pan Capacity 12 600 x 400mm Tray Capacity Optional Kit 76mm 3 76mm 3 ...

Page 6: ...ons 4 P10M Proofer Holding Cabinet 110 120V 1P N E 60HZ 1 45kW 220 240V 1P N E 50 60HZ 1 50kW 10 1 1 GN Gastronorm Pan Capacity 10 20 x 12 Hotel Steam Pan Capacity 10 18 x 13 Half Size Sheet Pan Capacity 74mm 27 8 ...

Page 7: ... N E 50 60HZ 1 95kW 230 240V 1P N E 50HZ 1 90kW 8 Full Size Sheet Pan Capacity 16 Half Size Sheet Pan Capacity 8 406 x 736mm 16 x 29 Tray Capacity 457 x 762mm 18 x 30 Tray Rack Set Optional 12 Full Size Sheet Pan Capacity 24 Half Size Sheet Pan Capacity 12 406 x 736mm 16 x 29 Tray Capacity 457 x 762mm 18 x 30 Tray Rack Set Optional 76mm 3 74mm 27 8 ...

Page 8: ... Left hand side 0mm 0 Right hand side 25mm 1 Each Proofer Holding Cabinet should be connected to an adequately protected power supply and an isolation switch mounted adjacent to but not behind the Proofer Holding Cabinet and must be readily accessible to the operator This switch must be clearly marked and readily accessible in case of fire Check that the electricity supply is correct to as shown o...

Page 9: ...water supply to check for water leaks NOTE The Proofer Holding Cabinet can be fitted with an optional Water Filter Kit Part No 234347 For fitting instructions refer to the Instruction Sheet supplied with the Water Filter Kit Correctly locate the Proofer Holding Cabinet into its final operating position and lock the front castors to retain the Proofer Holding Cabinet in it s location Water Connecti...

Page 10: ...tes when Thermostat Heating is turned ON and the elements are cycling ON to maintain set temperature Controls air temperature in the Proofer Holding Cabinet Temperature Range 0 85 C 32 185 F Proofing Range 20 40 C 65 105 F Holding Range 65 85 C 150 185 F Indicator light illuminates when Humidity Control is turned ON and elements are cycling ON to maintain the set humidity Controls the cabinet humi...

Page 11: ...ning Do not set the humidity to high as the product will become sticky and wet on the surface A silky to touch surface on the product is a general recommendation for correct humidity levels Avoid excess humidity levels as this will also create excess condensation in the interior of the cabinet NOTE Butter based product requires much less humidity than breads Ensure that power to the Proofer Holdin...

Page 12: ...oduct from Proofer Holding Cabinet interior using a mild anti bacterial detergent and hot water solution and a soft bristled brush f Dry Proofer Holding Cabinet thoroughly with a soft dry cloth Side Racks P8M P12M a To remove side racks for cleaning take hold of top and bottom of rack and lift front of rack upwards to disengage front upper and lower hangar studs b Swing the rack inwards c Take hol...

Page 13: ...uter surfaces of door Rinse with clean warm water and dry off b Dry the door thoroughly with a soft dry cloth c Clean door glass with a conventional glass cleaner Door Seal Clean door seal with warm water and a detergent solution using a soft sponge when required Should the door seal become dirty it can be removed for a more thorough cleaning should this be necessary a To remove 1 piece seal pull ...

Page 14: ...Service No Humidity Unit is in HOLD mode Low water level in trough No water in trough Humidity set too low Humidity Thermostat faulty Wet Element faulty Switch unit to PROOF mode Humidity is only generat ed in PROOF mode Solenoid or Float Switch faulty Call for service Refer to No Water Supply below Set humidity to higher setting Call for service Call for service No Water Supply Water turned Off a...

Page 15: ...ER SOLENOID HUMIDITY ON INDICATOR WATER TANK ELEMENT 650W 120V 600W 240V WATER TANK THERMOSTAT WATER LEVEL RELAY WATER LEVEL FLOAT SWITCH HEATING ELEMENT P8M P10M P85M8 700W 120V 800W 240V P12M P85M12 1200W 120V 1200W 240V HEATING THERMOSTAT 1 P HEATING CIRCUIT HUMIDITY CIRCUIT P4 4 P2 P3 P1 2 3 1 P4 4 P2 P3 P1 2 3 1 P4 4 P2 P3 P1 2 3 1 OFF PROOF HOLD SWITCH SETTINGS FUNCTION SWITCH FUSE 10A ...

Page 16: ...Top P85 M8 P85 M12 236299 Door Hinge Gasket Bottom P10 018947 Magnet Catch 234570 Door Seal P8 236474 Door Seal P10 234537 Door Seal P12 238584 Door Seal P85 M8 238606 Door Seal P85 M12 233528 Float Switch 234348 Water Solenoid 90 Outlet 240V 234349 Water Solenoid 90 Outlet 120V 025922 Adaptor Brass USA Canada only 021527 Washer Rubber USA Canada only 234216 Castor 75mm Rigid Rubber 234217 Castor ...

Page 17: ... unless otherwise stated Door reversal should only be carried out by a suitably competent person 1 Whilst supporting door unscrew and remove top door pivot bolt and Nord Lock washer from top door hinge assembly and lift the door off the bottom hinge 2 Remove top and bottom hinges and gaskets two screws 3 Remove four cover screws covering alternate hinge holes on RH side of proofer opening Refit co...

Page 18: ......

Reviews: