background image

 

BOOST SETUP 

!"#!$%$&$%'

())!%*+,)-.

/$&"*())!%

+0%"*.,"!!-,"

!"%*.)$#%

 

10) Setting SP1 (Set point):

 The SP value determines the duty cycle the solenoid will operate 

at when the gate pressure is reached. This is a value between 0 – 99. The larger the value, the more boost the 
turbocharger will produce.  Start the setup by increasing the SP value to 20. Bring the car onto boost and see what 
the maximum boost pressure is. Increase the value in small increments until you achieve your desired boost 
pressure. The SP value can also be adjusted while the car is on boost however, instead of the SP value being 
displayed, the boost pressure will be displayed so you know what pressure you are achieving. This is the easiest way 
to set your set points.

 

Press 

MODE

 to enter the menu and adjust the values using the 

UP

 and 

DOWN

 keys. Press 

MODE

 again to save the desired setting. 

 

 
 
 
 
 
 
 
 
 

11) Setting GP1 (Gate pressure):

 This feature helps bring boost on faster at lower rpm 

and will give an increase in torque. Start by setting the gate pressure 5 PSI below the desired boost pressure with the 
corresponding SP value e.g. if the desired boost pressure is 15 PSI, set the gate pressure to 10 PSI first and adjust 
from there. Adjust the value higher to increase the response of the turbocharger or decrease the value to reduce the 
response. If this setting is too close to target boost, you will get a boost spike. Press 

MODE

 to enter the menu and 

adjust the values using the 

UP

 and 

DOWN

 keys. Press 

MODE

 again to save the desired setting. 

 

 
 
 
 
 
 
 
 
 

12) Setting SN1 (Sensitivity):

 The sensitivity is how sensitive the e-Boost2 is to changes in 

the boost curve. Under normal circumstances the sensitivity is left at the factory set level of 20. If your boost curve is 
wavy through the rev range, reduce the sensitivity, if your boost curve drops off at the end of the rev range, increase 
the sensitivity. 

Note:

 do not increase this value higher than 30. Press 

MODE

 to enter the menu and adjust the values 

using the 

UP

 and 

DOWN

 keys. Press 

MODE

 again to save the desired setting. 

 
 
 
 
 
 
 
 
 
13) Hold 

MODE

 to exit the Boost Group. 

14) Repeat steps 10 – 13 for each Boost Group. 
15) Once all Boost Groups are set, Hold 

MODE

 in the Boost Group menu to enter Live Mode 