Technical data
20
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
14
Technical data
NCLS-30-UP6X-H1141
NCLS-30-UN6X-H1141
ID
100004248
100004249
Mounting position
Any
Notes for mounting
Only use the NCLS limit level sensors with original Turck pro-
cess adapters.
Required permittivity (ε
r
)
1.5
Pressure resistance
10 bar
Vacuum resistance
-1 bar
Temperature drift
Typ. 20 %
Ambient temperature
-10…+70 °C
Temperature of medium
0…+100 °C
Comment on
Temperature of medium
0…+130 °C for <1 h at an ambient temperature of 40 °C
Storage temperature
-20…+70 °C
CIP/SIP-compatible
Yes
Electrical data
Operating voltage
12…32 VDC
Power consumption
3 W
Switch-on time
< 0.3 s
Response time
< 0.2 s
Switching frequency
≤ 5 Hz
Insulation test voltage
≤ 0.5 kV
Communication protocol
IO-Link
SIO mode compatible
Yes
Number of digital outputs
2
Output function
4-wire, NO contact/NC contact,
PNP
4-wire, NO contact/NC contact,
NPN
Short-circuit protection
Yes
Wire breakage / reverse polar-
ity protection
Yes/yes
Protection class
III
Approvals
CE
EHEDG
IO-Link
IO-Link specification
V1.1
Parameterization
FDT/DTM
Physical transmission layer
Complies with 3-wire technology (PHY2)
Transmission rate
COM 2/38.4 kbps
Process data width
16-bit
Measured value information
14 bit
Switching point information
2 bit
Frame type
2.2
Contained in SIDI GSDML
Yes