background image

Product description

Functions and operating modes

8

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com

4

Product description

The capacitive limit level sensors of the NCLS series are contained in a stainless steel housing
with a PEEK sensor tip. The devices are provided with a metal M12 male connector for connect-
ing the sensor cable. An IO-Link interface is provided for setting and operating the devices. The
devices are provided with two outputs that can be set independently of each other. Output 1
can be used as a switching output or in IO-Link mode as required.

4.1

Device overview

mm [Inch]

31.2 [1.23]

47.2 [1.96]

94.8 [3.73]

Ø 21.6 [0.85]

Ø 18 [0.71]

22/7

G1/2

M12 × 1

Fig. 1: Dimensions

4.2

Properties and features

n

Media-contacting detection of limit levels in tanks and pipes

n

Detection of different substances (liquid, viscous, granular, powder form)

n

Hygienic PEEK sensor tip, CIP/SIP-compatible

n

Certified by EHEDG

n

Highly visible ring LED

n

12…32 VDC, < 1 W power consumption

n

Two digital outputs, separately adjustable as NO contact or NC contact

n

PNP, NPN or push-pull, switchable

n

IO-Link for parameterization and process values

n

Process connection G1/2” male thread, hygienic (in combination with Turck adapters)

n

4-pin connector device, M12 × 1

4.3

Operating principle

Capacitive sensors measure wear-free metallic (electrically conductive) and non-metallic (elec-
trically non-conductive) objects. When in direct contact with the media, the NCLS limit level
sensors are able to detect and differentiate different substances in liquid, viscous, granular or
powder form. Typical application areas are the detection of limit levels (max./min.) and changes
in media in tanks and pipes.

4.4

Functions and operating modes

The NCLS limit level sensor operates on the basis of the capacitive measurement principle.
When immersed, the active surface of the switch detects whether the medium is present or not.
The device is also able to differentiate between different media. The limit level sensor is
equipped with two parametrizable switching outputs. One of the switching outputs can be
used as an IO-Link interface, thus enabling direct access to the process values and parameters
of the device during normal operation. The device can only be parameterized via IO-Link.

Summary of Contents for 100004248

Page 1: ...Your Global Automation Partner Instructions for Use NCLS Limit Level Sensor...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 3: ...Operating principle 8 4 4 Functions and operating modes 8 4 5 Technical accessories 9 4 5 1 Mounting accessories 9 4 5 2 Connection accessories 10 5 Installing 11 5 1 General mounting instructions 11...

Page 4: ...Contents 4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 5: ...of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situatio...

Page 6: ...41 2 2 Scope of delivery The scope of delivery includes n Capacitive Limit Level Sensor n Quick Start Guide 2 3 Turck service Turck supports you with your projects from initial analysis to the commiss...

Page 7: ...al industries The device can be ex posed to process temperatures of between 0 100 C 130 C 1 h and a process pressure of up to 1 bar The devices may only be used as described in these instructions Any...

Page 8: ...adjustable as NO contact or NC contact n PNP NPN or push pull switchable n IO Link for parameterization and process values n Process connection G1 2 male thread hygienic in combination with Turck adap...

Page 9: ...Process adapter cylindrical welding sleeve without control bore for capacitive NCLS limit level sensors suitable for hygienic applications material 316L max temperature 140 C 16 0 63 G1 2 30 1 18 34...

Page 10: ...EL 6625013 Connection cable M12 female connector straight 4 pin cable length 2 m jacket material PVC black cULus approval 14 16 2 48 5 M12 x 1 L 50 5 RKC4 4T P7X2 2 TEL 6626162 Connection cable M12 fe...

Page 11: ...w in adapter Fig 2 Process connection with Turck process adapter 5 1 General mounting instructions n In principle the sensor can be installed in any position and in any location n Avoid mounting posit...

Page 12: ...k process adapter Use a wrench to tighten the sensor tightening torque 20 Nm 5 3 Mounting the sensor in hygienic applications according to EHEDG The sensor is certified for use in hygienic application...

Page 13: ...auxiliary tool to prevent damage from heat on the welding sleeve Carry out the welding as shown in the following figure Allow for a reasonable time between the welding seams in order to avoid heat da...

Page 14: ...08 4952 264 more turck com www turck com 6 Connection Use a suitable connection cable see Technical accessories Connect the device as shown in the wiring diagram 6 1 Wiring diagrams 3 2 4 1 1 4 2 3 ou...

Page 15: ...V01 01 2022 06 15 7 Commissioning After connecting and switching on the power supply the device is automatically ready for op eration...

Page 16: ...ning Green Switching state of output 1 indication function adjustable n Lit if output 1 OUT1 is active n Lit if output 1 OUT1 is inactive The LED ignores the set delay in both cases and switches immed...

Page 17: ...ettings are possible for each output n Output type PNP NPN push pull n Output function NO contact NO NC contact NC pulse width modulation PWM n Switching hysteresis at least 2 n Time delay for the swi...

Page 18: ...the device does not function as expected first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no...

Page 19: ...evice to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloade...

Page 20: ...C CIP SIP compatible Yes Electrical data Operating voltage 12 32 VDC Power consumption 3 W Switch on time 0 3 s Response time 0 2 s Switching frequency 5 Hz Insulation test voltage 0 5 kV Communicati...

Page 21: ...media Plastic PEEK Max tightening torque of housing nuts 20 Nm Process connection G male thread hygienic Electrical connection Male connector M12 1 Vibration resistance 2 Hz 1 mm Shock resistance 7 g...

Page 22: ...S A S 11 rue de Courtalin Bat C Magny Le Hongre F 77703 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckb...

Page 23: ...w turck ru Sweden Turck Sweden Office Fabriksstr ket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Sing...

Page 24: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100021577 2022 06 100021577...

Reviews: