V01.00 | 2021/05
11
5
Installing
5.1
Installing cylindrical devices
The maximum tightening torque of the housing nut is 25 Nm (M18 design) and 70 Nm (M30
design).
Install the device with the appropriate fixing accessories so that the front cap of the
devices fully protrudes from the surrounding area.
Observe the minimum distances between read/write heads.
Fig. 5: Mounting distances
a
b
c
d
M18
30 mm
54 mm
60 mm
10 mm
M30
45 mm
90 mm
90 mm
10 mm
Avoid metal in the proximity of the read/write head. Metal rails or similar objects must
not intersect the transmission zone.
Protect the device from heat radiation, rapid temperature fluctuations, severe contamin-
ation, electrostatic charge and mechanical damage.