V02.00 | 2020/08
19
7
Commissioning
The device is operational automatically once the cables are connected and the power supply is
switched on.
The read/write heads can be assigned additional parameters via the DTM in the PACTware 5.0
FDT frame application. FDT and DTM can be downloaded free of charge from
.
The planning and preparation of an RFID system require different measures, depending on the
application. Further information on this is provided in the RFID engineering manual.
7.1
Connecting read/write heads with the PC
In order to carry out extended parameter setting with the DTM, the read/write head must be
connected with a PC. The read/write heads can be connected with a PC via a TBEN-RFID inter-
face (e.g. TBEN-S2-2RFID-4DXP) or via the STW-RS485-USB interface converter.
7.1.1
Connecting the read/write head with a PC via the RFID interface
Connect the read/write head to the RFID interface converter using an appropriate
connection cable (e.g. RK4.5T-2RS4.5T/S2500).
Connect the RFID interface via a suitable Ethernet cable to the PC.
Connect the RFID interface to a power supply.
UHF RFID read/write head
e.g. TNxxx-Q175L200-H1147
RFID interface
TBEN-S2-2RFID-4DXP
RFID cable
e.g. RK4.5T-…-RS4.5T/S2500
Ethernet cable
e.g. RSSD-RJ45…
PC / Notebook
with Ethernet interface
Fig. 8: Connecting the read/write head with a PC via the TBEN-S2-2RFID-4DXP