For Your Safety
Intended use
10
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
3
For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1
Intended use
These devices are designed solely for use in industrial areas.
The read/write heads with an integrated RFID interface are used for contactless data exchange
with the BL ident tags in the Turck UHF RFID system. The following table shows the operating
frequency of the devices:
Type code
Operating frequency
Region
TN-UHF-…-EU-CDS
865…868 MHz
Europe
TN-UHF-…-NA-CDS
902…928 MHz
North America (USA, Canada, Mexico)
TN-UHF-…-CHN-CDS
920.5…924.5 MHz
China
TN-UHF-…-KOR-CDS
917…920.8 MHz
Korea
TN-UHF-…-BRA-CDS
915…928 MHz
Brazil
TN-UHF-…-RUS-CDS
866…868 MHz
Russia
TN-UHF-…-AUS-CDS
920…926 MHz
Australia
These devices may only be started up under the following conditions:
n
The particular frequency range is permissible for the use of UHF-RFID.
n
The operating frequency range of the devices is compliant with the permissible UHF RFID
range of the region.
n
A valid certification and/or approval is available for the region of use.
The integrated RFID interface enables the read/write heads to communicate directly with the
PLC or other higher-level systems. Read data is sent to the controller via the device. The device
can perform autonomous controller and diagnostics functions in order to reduce the workload
of the controller. The functions of devices can be programmed using the IEC 61131-3 compliant
CODESYS V3 programming software.
Four configurable digital channels are also provided for connecting digital sensors and actuat-
ors. The multiprotocol interfaces can be used as an EtherNet/IP device, Modbus TCP Turck slave,
or PROFINET RT device. In Modbus TCP systems the devices can also be used as masters.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
Summary of Contents for TN-UHF AUS-CDS Series
Page 1: ...Your Global Automation Partner Instructions for Use TN UHF CDS UHF Read Write Head ...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Page 97: ...V02 00 2020 08 97 Transfer the mapping to the POU Fig 94 Transferring the mapping to the POU ...