V02.00 | 2020/08
155
Process output data – UHF extended mode
Byte no.
Bit
PROFINET Modbus
EtherNet/
IP
7
6
5
4
3
2
1
0
0
0
Command code (CMDCUHF)
1
1
2
2
Loop counter for rapid processing (RCNT)
3
3
Memory area (DOM)
4
4
Start address (ADDR)
5
5
6
6
7
7
8
8
Length (LEN)
9
9
10
10
Length of EPC (SOUID)
11
11
reserved
12
12
Timeout (TOUT)
13
13
14
14
Read fragment number (RFN)
15
15
Write fragment number (WFN)
16
16
Reserved
17
17
Reserved
18
18
Reserved
19
19
Reserved
20
24
Write data Byte 0
21
25
Write data Byte 1
22
26
Write data Byte 2
23
27
Write data Byte 3
24
28
Write data Byte 4
25
29
Write data Byte 5
26
30
Write data Byte 6
27
31
Write data Byte 7
…
…
…
139
151
Write data Byte 127