V01.00 | 2019/04
17
6.4
Connecting external antennas
The device is provided with four RP-TNC sockets for connecting up to four external antennas.
The input impedance is 50 Ω.
Fig. 13: RP-TNC sockets for connecting external antennas
Connect external antennas with an RP-TNC antenna cable to the device (max. tightening
torque 0.8 Nm).