Commissioning
38
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
7.1.11
Setting the RSSI filter – Post read filter
The
Post Read Filter
tab enables parameters to be set in order to filter event messages.
The set filters do not reduce the data traffic on the air interface and are not suitable for multi-
tag applications with many tags or high passing speeds. All parameters and the settable values
are written in the DTM.
Example: Setting the RSSI filter
An RSSI filter makes it possible to prevent unwanted read operations. All read operations with
an RSSI outside of the set limit values are filtered out and not displayed.
At
Post Read Filter
Ò
RSSI filter
Ò
switch on the RSSI filter.
Fig. 39: Switching on the RSSI filter
Summary of Contents for TN-UHF LNX Series
Page 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Read Write Head ...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Page 75: ...V01 00 2019 04 75 Select RS485 RFID and confirm with OK Fig 62 Selecting the RS485 interface ...