10
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
Product Overview
Voltage dips, short interruptions
and
voltage variations immunity test
Port: AC mains;
Level:
100 % duration: 1 cycle and 250 cycles (50 Hz);
40 % duration: 10 cycles (50 Hz);
70 % duration: 25 cycles (50 Hz);
Phase: 0°-180°
Test executed on the 230 VAC side of the power supply
EN 61000-4-11
Port: DC mains; Level:
0% duration: 10ms 20 spaces by 1s
Test executed on the 24Vdc of the EUT
EN 61000-4-29
Durability information
Backlight service life (LED type)
20000 hours or more
(Time of continuos operation until the brightness of the backlight reaches 50 % of
the rated value when the surrounding air temperature is 25 °C).
NOTE
Extended use in environments where the surrounding air temperature is 40 °C or higher may
degrade backlight quality/reliability/durability.