MASTERseries - Release 7.0
31
MASTERseries Quick Start Guide
Local Management - Logging in to the FLEXmaster
4. Set the Line delay to
50
milliseconds and the
Character delay to
5
milliseconds.
5. Click OK.
Procomm Users
If you are unsure of the baud rate set on a module, connect to that module at 19200 baud and press
the
R
key. If there is no response, use 9600 baud using the same approach. If there is a baud rate
mismatch between Procomm and the master module, the master module could reboot. To prevent
this:
1. Go to Options> Data Options > Setup Files...
2. Select the Data tab.
3. Select Terminal Options.
4. Set the Enquiry Type field to OFF.
Other versions of Procomm might require you to navigate to the Enquiry Type field differently.
Consult your Procomm manual for more information.
Additional Settings
Hardware flow control: Off
XON/XOFF flow control: Off
Use DTR (for hang-up): Off
Monitor DCD (carrier): Off
Exit on hang-up: Off