72
button input source selects a non-subsystem, it is set to the traditional mode. Non-jog
cannot be used in subprograms, and it cannot be stepped back to the main program after
use.
New method: When the button input source is set to a subsystem, a new method (jog
mode) must be set, which is faster.
The operation interface is shown below:
Figure 6-7 Key definition
6.2.2 Log print settings
For the consideration of system running speed and hard disk storage capacity, the
setting of print log is divided into four levels:
【
Error
】
<-
【
Warning
】
<-
【
Information
】
<-
【
Debug
】
. Select high level log, it will
automatically print low level log.
The Log is divided into the foreground log and the background log. The foreground
log is displayed in the running log column of the teach pendant interface, and the
background log is saved in the log folder, which needs to be copied out and checked with a
computer. Background logs are usually more detailed than foreground logs. As a user, you
usually only need to know the information in the front desk log .