84
slave status error
0x00010014
Accessory error (status code)*/
0x00010015
Station address is missing (or slave station is missing)-FPRD to
AL_STATUS failed*/
0x00010017
SoE mbox send: work counter error*/
0x00010018
SoE mbox write response error*/
0x00010019
CoE mbox SDO abort*/
0x0001001a
The client registration is deleted, and ecatConfigureMaster of other
threads (RAS) */may be called
0x0001001b
Redundancy: the line is repaired*/
0x0001001c
FoM mbox aborted*/
0x0001001d
Invalid mailbox data received*/
0x0001001e
The PDI watchdog expires on the slave station, which is determined by
IST*/
0x0001001f
Unsupported slave (if redundancy is activated, and the slave does not
fully support automatic shutdown)*/
0x00010020
Slave station in unexpected state*/
0x00010021
All slave devices are running*/
0x00010022
VOE mbox send: work counter error*/
0x00010023
EEPROM checksum error detected*/
0x00010024
Testing*/
0x00010025
Connection redundancy change*/
0x00010026
Slave station in unexpected state*/
0x00010027
Slave error (AL status code)*/
0x00030002
The communication file does not match the actual connection status,
such as expanding external axis, expanding IO board