Simret 4000 Instructions, Issue 10, Jan 2011
© 1994-2011, Turnkey Instruments Ltd. Page 13 of 17
Change Settings Menu
Highlight the item and single-click to change its state. The default states are shown Note some items
will only appear conditionally depending on the state of other items.
Bluetooth
No
YES to
switch on Bluetooth
NO to switch off
Swap BT port
Yes
YES is normal setting
NO for special versions
I/O expansion
No
YES for input/output expansion
NO for no expansion
Auto-alignment
Yes
YES to auto-align with direction of travel
NO for manual alignment
Brake Effort
Yes
YES to
measure brake effort or ratio
NO to measure deceleration
Allow Coasting
Yes
YES for rail coasting mode
NO for normal operation
Metric Units
Yes
YES for results in metric units
NO for imperial units
metre/sec/sec No
YES for results in metres/sec/sec
NO for %g or g
Results in %g
Yes
YES for results in units of %g
NO for units of g
External trig
Yes
YES to start at external trigger
NO to self-start at deceleration
Delay in Mean
No
YES to include the brake delay in the mean
calculation
NO to exclude (gives higher readings)
MFDD markers
Yes
YES to mark 80% and 10%V on graphs
NO for no MFDD markers
Calc. Distance
Yes
YES to calculate stopping distance
NO do not calculated
Slope at stop
No
YES use gradient at stop as reference
NO use gradient at arming
Pedal Force
No
YES to use pedal force transducer
NO don’t use
Sampling Rate
NRML
NRML=40 samples/sec
FAST=400 samples/sec
Beeper ON
ON means beeper is on
Speedo Beep
ON
ON means Speedo Beep is on at 10, 20, 30,
and 40 kph/mph
Screen light
ON
ON means screen light is on
PIN for edit
No
YES means PIN number required for
changing setup
PIN to use
No
YES means PIN number required to use
instrument
Mark for print
Yes
YES to mark all tests for print selection
Print graphs
Yes
YES to print graphs
NO don’t print graphs
Overlay graphs
Yes
YES to print graphs overlaid
NO print separate graphs
Print settings
Yes
YES to print test settings with results
NO don’t print settings