Speed Gate Turnstile User Manual
The sensitivity setting when the gate hit pedestrian or in the face of obstacle, the
smaller the value is , the higher sensitivity . Note: this setting only be effective when
D17 was set . Values 1-
99 default value: 10
< D-19 >
KP
Set motor parameters "value 1-
999" default value: 160 do not change at will
< D-20 >
KI
Set the motor parameter "value 1-200" default value: 0 do not change at will
< D-23 >
Physical clamping reaction time
This adjustment needs to contact the manufacturer's technical staff "value 1-100"
default value: 0 do not change at will.
< D-26 >
counter strength (slave)
When the swinging door is in the closed non-working state, the reverse force can
be adjusted when the swinging door is forced open by the external force. The
larger the value, the greater the force ( value 1-20), default
:
14
www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099