[13]
I: Remote Lane Control -
Touchscreen Connection Options-
1) 485 communication – A Shielded/Stranded 18 -22 awg/4-conductor cable
rated for 485 communications is required to run from the control computer, to the
first lane’s PIO. Then daisy chain to each of the other lane’s PIOs (J19 + J20) in
order to operate the RLC with full functionality. Each PIO is addressed via the on-
board rotary switch from number 1 to the total number of lanes.
2) Ethernet – An Ethernet cable should be run from each PIO to a DHCP switch or
router, a separate cable should be run from the DHCP device to the control
computer. IPs will need to be saved to each PIO and then set in the computer.
J: Earth Ground
-
An earth ground is required to each pedestal’s base
for warranty coverage. Pictures of both ends of the ground are required to
enable warranty.
6.
REMOTE LANE CONTROLLERS (RLC)
(optional)
A: Push-Button Controller (RLC-PB)
Pictured above is the Pushbutton Remote Lane Controller (RLC-PB). Across the top of
the desktop controller provides the number of lanes controlled by this RLC. The left
column provides the functions that the turnstile is capable of operating remotely.