[9]
B: Multiple Lanes
- When there are two or more lanes being installed, it is
necessary to understand the placement of the pedestals and board locations. Referencing
from the unsecured side, the first pedestal is on the right hand side and will contain only
a PIO board, and the last pedestal farthest to the left side will contain only a SIO board.
All of the middle pedestals will contain both a PIO and a SIO board. If the pedestals are
mounted correctly, then each lane will have a PIO on the right and a SIO on the left when
facing the lane from the unsecured side.
C: Standard Power Supply
- 120Vac/24Vdc 10A Power Supply
Verify output power is between 24-25VDC on two pin connector (J11) before
connecting it to PIO. The Life Safety power supply provided with the units is capable
of handling 1 – 2 OBSG-HG-CV speedgates. It should be located within 50 feet of the
first pedestal. A separate 16-18 awg/2 conductor shall be “homerun” to each PIO. The
power is then transferred to the adjacent pedestal’s SIO via an 18 awg/4 conductor
interconnection cable. Each lane draws 10 amps at peak. A 240w 24VDC 10A power
supply is provided by (see below) for each suite of up to 2 lanes. 120Vac 15A circuit must
be provided.
Unsecured Side
Secondary Pedestal
Ped 2
SIO
Primary Pedestal
Ped 1
PIO
Secured Side
www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099