background image

 

Each burner has flame failure protection. To light the main burner the pilot must be lit first. The following steps must 

be taken. 

 

1.  Press  in  gas  cock  knob  and  turn  anti-clockwise  till  pilot  symbol  lines  up  with  indicator  on  control  panel. 

There is a stop at this point. Light Pilot by pressing piezo button for a couple of seconds or light by match or 

taper. Hold gas cock in for approximately 5-7 seconds, then release knob. The pilot should now stay on. 

 

2.  Turn gas cock knob to indicated settings as required. The boiling burner can now be operated off the pilot. 

 

 

3.  It is recommended to turn off all pilot lights at the finish of the day’s operations. This conserves energy and 

reduces operating costs. 

 

GRILL COMPARTMENT (Lighting Procedure) 

 

1.  Press in gas cock knob to pilot symbol and stop (anti-clockwise). 

2.  Pilot is lit by a piezo press button adjacent to gas cock. Press button several times until pilot remains alight or 

you can manually  light  the  plate by  match,  then  turn  gas cock to the  desired setting as  indicated  by  flame 

symbols for satisfactory flame. Pilot can be seen through viewing hole. 

3.  Warning when using grilling compartment – remember solid plate is heating also. 

4.  Pre-heat  grill  plate  for  approximately  5-10  minutes  before  placing  products  on  to  the  plate.  This  preveits 

sticking of meat products, then reduce flame height to prevent undue flaring of the flame while cooking. Then 

pre-heat the grill toasting area as above. 

5.  It is recommended that the appliance be kept clean to prevent excess fat build up. Always empty fat collection 

tray daily. 

 

Do not use any caustic base cleaning products. Damage to the appliance could result and void warranty. 

 

 

SERVICING 

(Must only be carried out by Authorised Personnel) 

 

1. 

To remove burners tilt burner up from the front, pull forward if required for servicing. 

2. 

Service of combination gas controls and burners must be carried out by an authorized person only. 

3. 

When the piezo button does not work, please use manual lighting of the pilots. 

 

For gas service call authorized local gas agent or contact manufacturer for service information should appliance fail to 

operate. 

Phone:  (613) 9543 9577 

Fax: 

(613) 9544 1487 

Or you call local Supertron Agent contact us. 

 

CONVERSION INSTUCTIONS – NG TO LPG 

 

1. 

Conversion must not be carried out without consulting manufacturer or agent in the region. 

2. 

(a)  Remove N.G. injectors 

(b)  Remove N.G. regulator  

(c)  Replace pilot injector with L.P. type 

(d)  Set appliance operating pressure to 2.75 kpa 

 

DIAGRAM 

 

 

 