4
Each burner has flame failure protection. To light the main burner the pilot must be lit first. The following steps must
be taken.
1. Press in gas cock knob and turn anti-clockwise till pilot symbol lines up with indicator on control panel.
There is a stop at this point. Light Pilot by pressing piezo button for a couple of seconds or light by match or
taper. Hold gas cock in for approximately 5-7 seconds, then release knob. The pilot should now stay on.
2. Turn gas cock knob to indicated settings as required. The boiling burner can now be operated off the pilot.
3. It is recommended to turn off all pilot lights at the finish of the day’s operations. This conserves energy and
reduces operating costs.
GRILL COMPARTMENT (Lighting Procedure)
1. Press in gas cock knob to pilot symbol and stop (anti-clockwise).
2. Pilot is lit by a piezo press button adjacent to gas cock. Press button several times until pilot remains alight or
you can manually light the plate by match, then turn gas cock to the desired setting as indicated by flame
symbols for satisfactory flame. Pilot can be seen through viewing hole.
3. Warning when using grilling compartment – remember solid plate is heating also.
4. Pre-heat grill plate for approximately 5-10 minutes before placing products on to the plate. This preveits
sticking of meat products, then reduce flame height to prevent undue flaring of the flame while cooking. Then
pre-heat the grill toasting area as above.
5. It is recommended that the appliance be kept clean to prevent excess fat build up. Always empty fat collection
tray daily.
Do not use any caustic base cleaning products. Damage to the appliance could result and void warranty.
SERVICING
(Must only be carried out by Authorised Personnel)
1.
To remove burners tilt burner up from the front, pull forward if required for servicing.
2.
Service of combination gas controls and burners must be carried out by an authorized person only.
3.
When the piezo button does not work, please use manual lighting of the pilots.
For gas service call authorized local gas agent or contact manufacturer for service information should appliance fail to
operate.
Phone: (613) 9543 9577
Fax:
(613) 9544 1487
Or you call local Supertron Agent contact us.
CONVERSION INSTUCTIONS – NG TO LPG
1.
Conversion must not be carried out without consulting manufacturer or agent in the region.
2.
(a) Remove N.G. injectors
(b) Remove N.G. regulator
(c) Replace pilot injector with L.P. type
(d) Set appliance operating pressure to 2.75 kpa
DIAGRAM