General Information
Environmental Conditions
Ambient Temperature
0°C to 38°C (32°F to 100°F)
Humidity
0% to 90% R.H.
Ambient Pressure
0.8 to 1.2 Bar (11.8 psia to 17.6 psia)
Ventilation
Use in a well-ventilated area away from excess dust, dirt, and moisture.
Cleaning
With unit OFF and unplugged, exterior surfaces
may be wiped clean using a damp cloth.
Attaching 230V (European style) plugs
(see diagram):
NOTE: Use plug appropriate for local area and codes.
Only qualified personnel should perform wiring.
Overcurrent protection should be provided external
to the heater unit within plug type shown or similar fusing.
Protective Earthing
The yellow and green ground wire in the power cable is attached directly to the aluminum
base plate inside the heater via a dedicated screw terminal. Additional protective earthing
can be attached to the aluminum base plate if desired.
Basic Operation
1.
Turn SKORPION air heater ON
using two switches:
1.1. Switch S1 (blower) sends power to the blower and to heater switch S2.
1.2. Switch S2 (heater) sends power to the heater control circuit.
1.3. Note, for heater safety, S2 (heater) cannot turn ON without S1 (blower) ON.
2.
Adjust airflow
via a rotational air damper at the blower inlet.
3.
Adjust temperature set point
with the UP/DOWN arrows on the temperature controller.
Heater will ramp to temperature.
3.1. The process temperature is measured with an internal type “K” thermocouple located at
the end of an element inside the stainless housing.
4.
When
turning the heater off
the heater power (S2) may be turned off and the blower (S1)
left on to cool the heater housing assembly. This is suggested to prevent burn injury of
personnel around the heater but is not necessary for safety of the heater element.
3
Summary of Contents for SKORPION F075615
Page 9: ...SKORPION 1 5kW 3 0kW 8 ...
Page 10: ...SKORPION 4 5kW 9 ...
Page 11: ...SKORPION Without Blower 1 5kW 3 0kW 4 5kW 10 ...