ACM 400 S motor control unit
14 / 24
7) Putting into Service
[X2]
If the control unit has been installed and connected as described, it can now be put
into service:
non-connected inputs
are closed, as far as necessary,
e.g. at the inputs for ...
Emergency stop (page
Fehler! Textmarke nicht definiert.
)
Photoelectric barrier (page
Fehler! Textmarke nicht definiert.
)
Closing edge safety device (page
Fehler! Textmarke nicht definiert.
)
Ensure safety, regarding the remaining part of the
whole system
, in particular ...
ensure that when the motor is started up nobody can be injured and the
system cannot be damaged.
It makes sense, when switching the gate on for the first time, for the gate to be in the
middle
of the gate path, to allow sufficient reaction time if unexpected movements
occur.
If you now switch on the system voltage, a complete
self-test
(see page 17) is now
carried out.
[X2.1] The
display
first displays
"88"
and then
"CH"
as an indication that the self-
test is running.
a) The LEDs on the printed circuit board
signal the switched condition of the respective
inputs / outputs:
[X6.1] At terminals
23...39
, lit LEDs mean that the respective
inputs
have been
triggered or are not closed off.
[X6.2] At terminals
40...42
, lit LEDs mean that the respective
limit switch has
triggered
, i.e. the gate is in this limit position.
[X2.5] The lit LEDs
under the display
mean that the outputs for
light and warning
light
conduct voltage at
terminals 9...11
.
[X2.1] The
left-hand display point
lights up if a signal from the
speed sensor
is
received at
terminals 19...20
.
[X2.1] The
right-hand display point
lights up, if
automatic closing
is activated.
b) The LEDs on the membrane keyboard
[X5]
signal the
gate status
and indicate error statuses:
[X5.1] The
"Running"
LED lights up...
continuously during normal operation
flashes if errors occur according to the "error messages" table.
[X5.2] The LED
"A"
(gate) lights up...
continuously, if the gate is in the limit position "Open",
does not (= off), if the gate is in the limit position "Closed",
flashes slowly (0.5Hz), if the gate is stopped along the gate’s path,
flashes quickly (4 Hz), if the gate is moving open or closed.
[X5.3] The LED
"B"
(radio) lights up if a valid
radio command
has been analysed.
[X5.4] The LED
"S"
lights up if an error has been detected (e.g. a sensor triggered or
Emergency Stop or undervoltage).