16
TP11KC-DX
Jun 2017
11.
Install the Hydraulic Fittings, Hoses and Return Lines
A.
Fitting & Hose Connecting:
1.
First screw on the hose fitting connectors on the cylinder’s lower end ports. (Fig. 9a)
2.
Connect the longest hose from the cylinder in Off side column to the top of Main side column.
Remember to route the hose through the hook on cross beam. (Fig. 9b & 9c)
3.
Then from the T-fitting inside column, connect the shortest length hose directly down to the main
inside cylinder connector. (Fig. 9d)
4.
Another middle length hose from the T-fitting goes to the motor pump through a hole on the side of
the column. (Fig. 9d)
Fig. 9a Fig. 9b
Fig. 9c Fig 9d
B.
Return Line Connection (blue air-line)
1.
Screw in an elbow air-line fitting on the top end of the off side cylinder (Fig. 9b).
2.
Screw in another T air-line fitting on the top end of main side cylinder also. (Fig. 9c)
3.
Connect the return line from off side cylinder to main side cylinder through fittings.