C2-6104A O
PERATION
M
ANUAL
40
DO NOT ADJUST THESE ITEMS UNLESS YOU’RE CERTAIN YOU KNOW
WHAT YOU’RE DOING! THE ONLY METHOD TO UNDO CERTAIN CHANGES
IS TO UPDATE THE FIRMWARE.
TRY USING THE AUTOSET, SHRINK, SHRINK POS, TL & BR ADJUSTMENTS
FIRST.
Making adjustments here risks creating a non-standard resolution that is not
displayable on a monitor. The resolutions and values within the database are
industry standards and should not normally be altered by the user. That said, there
might be times when it is necessary to create a custom resolution with specific
parameters. If circumstances require you to make such a change, please read the
following specific notes:
1. Any changes made to this database take effect instantly and are also stored
immediately in non-volatile memory.
2. Since this database is used for both input and output image processing, altering
a resolution that is used for both (e.g. 1024x768 input and 1024x768 output)
may give undesired effects.
Change the value to select resolution you want to alter.
Typically, the image number currently being used for input or
output would be already be selected otherwise immediate
feedback to your changes will not be available via your monitor.
This adjustment specifies whether the image is interlaced or progressive scan. It
toggles simply On or Off, so there are no flashing brackets.
Course Frequency Adjust
The H freq.crse (Horizontal Sync Frequency - Course) adjustment provides the
option for changing the Horizontal Sync timing Frequency in 100 Hz steps.
Fine Frequency Adjust
800 x 600 60 Hz
Image to adjust [ 17]
800 x 600 60 Hz
Interlaced [ Off]
800 x 600 60 Hz
H.freq.crse [37.879] kHz
800 x 600 60 Hz
H.freq.fine [37.879] kHz