PDF-MG-DA-61x v1.0
4
Rear panel
MG-DA-614 shown
Number Name
Description
1
INPUT
Type-A female HDMI input port to connect a HDMI source
2
OUTPUTS
Four type-A female HDMI output ports to connect HDMI displays
3
DC 5V*
DC barrel port to connect a DC AC power adapter
*12V for MG-DA-618
DIP switch operation
EDID management
The Extended Display Identification Data (EDID) is used by the source device to match its video resolution
with the connected display. By default, the source device obtains its EDID from the first connected display.
If you have a MG-DA-618, use the DIP switch on the front panel and the 4-pin DIP switch on the rear panel
in combination to set the EDID to a fixed value to ensure compatibility in video resolution.
Switch Status
Description
L.RES
The splitter reads all EDID information from all connected displays and chooses
the one with lowest resolution passing to the source.
PRESET
In this mode, the 4-pin DIP switch on the rear panel can be used to select a
predefined EDID and customize a specific EDID as need.
H.RES
The splitter reads all EDID information from all connected displays and chooses
the one with highest resolution passing to the source.
1
2
4
3
IN
1
2
3
DC 5V
IN
Front DIP switch of the MG-DA-618