Rebar Scanner A60+
32
Press the ENTER key to reset and eliminate the environmental
influence.
4. According to design data or experience, the rebar direction is
determined. If rebar direction is not determined, horizontal &
longitudinal direction and position of grid pattern rebar are detected
according to rebar location function of instrument.
5. The trolley and probe are placed on the surface of detected body
and the probe is moved at uniform speed in parallel with detected
rebar.
The speed should be less than
20mm/s.
According to the
direction shown on the right upper corner, rebar that is vertical to the
direction of moving trolley is detected. At this time, one black block
shown on the screen is moved horizontally from the left to the right.
After hearing the alarm, detected rebar is showed on the screen in the
formation of small black block. At the same time, covering layer
thickness of current detected rebar is showed under the T. During
continuing to move the trolley to the right, when D that the trolley
moves is not less than 500/1000/2000, it is prompted by means of
continuous alarm. At this time, press the SAVE key to save detection
results into current set project No. and press the ESC key to return the
interface of selecting scanning mode.