39
Twin Disc, Incorporated
Operation
Power Shift Transmission System Operator’s Manual #1020510
Based on all discreet input signals and J1939 Data Bus input signals, the
electronic control sends signals out to various devices that cause the fracturing
rig operation. The outputs are sent discreetly and also via the J1939 Data
Bus.
The Discreet Output Signals Are:
q
Electrical current to the transmission range valve clutch coils used
to engage the proper clutches to provide the transmission range
desired
q
Electrical current to the lockup clutch valve coil used to apply the
converter lockup clutch as needed
The S.A.E. J1939 Data Bus Output Signals Are:
q
Signals to the display unit, indicating the transmission range and
direction
q
Transmission input and output speed
q
Transmission system oil temperature
q
Status of transmission filter differential pressure switch
q
Status of transmission oil level switch
q
Transmission configuration and # of gears, and ratios
q
Current gear status
Summary of Contents for TA-90-8501