Heater valve will
not switch from
Hi to Low and
vice versa
1.
Low battery pack. Replace 4 AA batteries.
2.
Ground wire not connected. Connect ground wire to chassis and remove and re
install 4 AA batteries to clear memory.
3.
Defective gas valve. Contact local dealer to replace gas valve.
Batteries in the
battery pack
drain fast.
1. The battery pack is switch to DC MOTOR instead of LATCHING SOLENOID.
Make sure that the battery pack switch is set to LATCHING SOLENOID.
Front grille
deteriorates
1.
Tip angle exceeding 30 degrees such that products of combustions vent out to the
front grille instead of out the top of the heater. Correct installation and make sure
only radiant heat passes through the front grille.
2.
Windy condition. Excessive wind disrupts flow of combustion products such that
combustion products flow though the front grille instead of out the top of the
heater. Locate heater in less windy conditions.
Burner makes
loud rumbling
noise during
operation.
Burner does not
glow and flares
out.
1.
Damaged burner. Contact local dealer to replace burner.
Heater operates
but makes
continuous
beeps.
1.
Module exceeds designed operating temperature. Improper installation such that
products of combustion flows through the front grille instead of out the top of
heater. This could be due to exceeding the 30 degree tip angle or windy
conditions. Correct installation such that only radiant heat passes through the
front grille.
19