GAS SAFETY REQUIREMENTS
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of
gas, either natural gas (NG) or Liquid Propane (LP) gas and make sure that the marking on the data plate (rating
plate) matches the gas being supplied to the side burner. This information is found on the rating/data plate,
located on the inside back of the front panel.
All gas connections should be made by a qualified technician and in accordance with local codes and
ordinances. The installation must conform with local codes or, in the absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas Propane Installation Code, CSA B149.1 or
CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
WARNING:
ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN CONTACT WITH ANY HOT
SURFACE OF THE SIDE BURNER.
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY.
L.P. GAS SAFETY REQUIREMENT
The LP-gas supply cylinder must be constructed and marked in accordance with the
Specifications for LP-gas
Cylinders
of the U.S. Department of Transportation (D.O.T.) or the National Standards of Canada
CAN/CSA-
B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, and Commission,
as
applicable; and
1. Provided with a listed overfilling prevention device.
2. Provided with a cylinder connection device compatible with the connection for outdoor cooking
appliances.
•
It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include a collar to
protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal.
•
Do not operate the side burner indoors or in any enclosed area. If the side burner is not in use, the gas
must be turned off at the supply cylinder. If the side burner is to be stored indoors, disconnect the gas
supply cylinder and leave the cylinder outdoors out of reach of children and must not be stored in a
building, garage or any other enclosed area.