background image

 

LIQUID PROPANE GAS CONNECTION – T

WIN 

E

AGLES 

T

EPPANYAKI 

G

RIDDLE

 

 

If your Teppanyaki Griddle is for Liquid Propane application, a factory supplied L.P regulator is set for 11” WC and 

is for use with L.P. gas only.  The factory-supplied regulator and hose must be used with a 20 lb. L.P. cylinder.   

LP Gas Hose

 

• The gas supply hose should be inspected prior to each use.  Do not use a gas hose that has abrasions, cuts, or 

excessive wear. 

•The gas supply must be turned off at the LP Gas supply cylinder and the LP Gas supply cylinder must be 

disconnected from the regulator when this outdoor cooking gas appliance is not in use. 

• When your Teppanyaki Griddle is stored indoors, remove and store the LP Gas cylinder outdoors in a protected, 

cool, and dry location out of reach of children.  The cylinder should not be stored in a building, garage, or any other 

enclosed area. 

LP gas cylinder

 

• Store the cylinder in an upright position so that the cylinder valve is at the top.  This will ensure proper vapor 

withdrawal. 

•The cylinder used must include a collar to protect the cylinder valve. 

• Store any spare or extra gas cylinder(s) at least 15 feet from the Teppanyaki Griddle other open flame, heat-

producing appliance(s) or heat source in a cool, well-ventilated outdoor location.   

Note: 

An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor level. 

The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP gas supply 

cylinder in place. This shall be accomplished by one of the following: 

 

a.

 

One side of the enclosure shall be fully open; or 

 

b.

 

For an enclosure having four sides, a top and a bottom: At least two ventilation openings at 

cylinder valve level shall be provided in the sidewall, equally sized, spaced at 180 degrees (3.14 rad), 

and unobstructed. Each opening shall have a total free area of not less than 1/2 square inch per pound 

(7.1 cm

2

/kg) of stored fuel capacity and not less than a total free area of 10 square inches (64.5 cm

2

). 

 

c.

 

Ventilation opening(s) shall be provided at floor level and shall have a total free area of not less 

than ½" square inch per pound (7.1 cm2/kg) of stored fuel capacity and not less than a total free area 

of 10 square inches (64.5 cm2).  If ventilation openings at floor level are in a sidewall, there shall be at 

least two openings. The bottom of the openings shall be at floor level and the upper edge no more than 

5 inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 

rad) and unobstructed.  

 

Summary of Contents for TETG30-B

Page 1: ...TEPPANYAKI GRIDDLE USE AND CARE MANUAL PN 18613C 07 10 Models TETG30 B ...

Page 2: ...ration Thank you and welcome TWIN EAGLES _____________________________________________________________________ FOR YOUR RECORDS Please retain a copy of your sales receipt for warranty claims Please record the following information and refer to them when contacting the company or an authorized service agent This information is found on the rating serial plate located on the inside wall of the left ...

Page 3: ... of power failure do not attempt to operate this appliance All gas installations electrical connections and gas conversions must be performed by a qualified technician or authorized service agent This appliance is not intended for commercial use FOR YOUR SAFETY If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier or you...

Page 4: ...ustible materials gasoline and other flammable vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debris 8 Check all gas connections for leaks with soapy water solution and brush Never use an open flame Reference page 8 for leak test procedure 9 Check flexible hoses for cuts a...

Page 5: ...ATERIAL ENCLOSURE 2 o CUT OUT DIMENSIONS FOR BUILT IN 3 GAS REQUIREMENTS 4 o NATURAL GAS HOOK UP 5 o LP GAS HOSE 6 o LP GAS CYLINDER 6 o BOTTLED LP GAS HOOK UP 7 o GAS LEAK TEST 8 OPERATING INSTRUCTIONS 9 CLEANING MAINTENANCE o GRIDDLE PLATE 9 o GREASE TRAY 10 o FLUE COVER ASSEMBLY 10 o SPIDER AND INSECT WARNING 10 EXPLODED VIEW DRAWING 11 REPLACEMENT PARTS LIST 12 WARRANTY 13 HOW TO OBTAIN SERVIC...

Page 6: ...ted at120V 60Hz 900W and 8A Propane or LP If your griddle is factory built for L P the regulator supplied is set for 11 water column and is for use with L P gas only The factory supplied regulator and hose must be used with a 20 lb L P cylinder Do not use any replacement regulator other than that specified by Twin Eagles Natural Gas or NG If the griddle is factory built for natural gas the regulat...

Page 7: ...les and or boats This appliance must be on a level stable surface in an area clear of combustible material An asphalt surface may not be acceptable for this purpose NON COMBUSTIBLE ENCLOSURE The Teppanyaki Griddle must be installed in a NON COMBUSTIBLE ENCLOSURE ONLY The determination of whether a location is combustible or non combustible construction is made by the local fire marshal building in...

Page 8: ...1 2 24 1 4 30 1 8 4 6 1 2 11 1 2 Freestanding Applications The Twin Eagles Teppanyaki Griddle may be installed into the Twin Eagles 30 freestanding grill base TEGB30 B The freestanding configurations allow 12 from the sides and rear to combustible construction while in operation 3 ...

Page 9: ...an and in accordance with local codes and ordinances The installation must conform with local codes or in the absence of local codes with either the national Fuel Gas Code ANSI Z223 1 NFPA 54 or CAN CGA B149 1 Natural Gas Installation Code or CAN CGA B149 2 Propane Installation Code All gas installations conversions and or adjustments must be performed by an authorized service agent WARNING CHECK ...

Page 10: ...supply piping system at test pressures equal to or less than 1 2 psi A typical natural gas installation is shown below Make sure the factory supplied regulator is used and installed with the arrow mark on the regulator pointing in the same direction as the gas flow going from the supply line to the Teppanyaki Griddle The regulator is preinstalled onto the end of the Manifold Use only the regulator...

Page 11: ...pen flame heat producing appliance s or heat source in a cool well ventilated outdoor location Note An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor level The effectiveness of the opening s for purposes of ventilation shall be determined with the LP gas supply cylinder in place This shall be accomplished by one of the following a One side of the enclo...

Page 12: ...to the 3 8 Flare end of the brass coupling on the unit using a 3 4 open wrench Do not apply pipe sealant 4 Connect the regulator to the LP cylinder Do not use any tools Hand tighten the regulator 5 Check for leaks using a soapy water solution 6 See figure above for a typical LP gas hook up 7 To disconnect after use turn the burner knob to the OFF position Close the Cylinder Valve by turning the Ha...

Page 13: ...y the factory supplied hose and regulator must be used Use only replacement regulator and hose assemblies specified by Twin Eagles LEAK TEST 1 Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap and half water 2 Confirm that all control knobs are in the OFF position 3 Turn the main gas valve supply ON 4 Apply leak testing solution by spraying on the pip...

Page 14: ... set to 6 To shut down turn the thermostat and rocker switch to the OFF position 7 For complete shutdown close the valve at the gas supply CAUTION Do not leave the Teppanyaki griddle unattended while cooking THE GRIDDLE PLATE CAN NOT BE LIT MANUALLY CLEANING AND MAINTENANCE TWIN EAGLES TEPPANYAKI GRIDDLE General Overview Proper care maintenance and cleaning will help ensure a long life of your Tep...

Page 15: ...nd lift the tray to remove it from the griddle plate assembly Wipe the grease tray clean with a cloth and a hot soapy solution Make sure the grease tray is fully inserted back into the Teppanyaki Griddle again Flue Cover Assembly The Flue Cover Assembly is located at the back of the griddle plate assembly Wipe the flue cover clean with a cloth You may also remove it for cleaning with a hot soapy s...

Page 16: ...EXPLODED VIEW TWIN EAGLES TEPPANYAKI GRIDDLE 2 1 3 4 5 6 8 7 9 10a 11 11 12 10b 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 29 32 31 33 34 See Detail Detail ...

Page 17: ... 14 S14160 Tinnerman Clip 2 15 S13136 Printed Chrome Knob Bezel 2 16 S16113 Red Pilot Light 2 17 S13154 Chrome Knob 2 18 S16131 Rocker Switch 1 19 S16196 Blue Illuminated Switch 1 20 S15312 Thermostat 2 21 S16192 LED Holder 2 22 S20961Y Front Panel Assembly 1 23 S12602 Coupling Brass 3 8 Flare x FIP LP Model Only 1 24 S15302 LP Regulator LP Models Only 1 25 S15303 Natural Gas Regulator NG Models O...

Page 18: ...roper installation or improper operation unauthorized adjustments or calibrations dings dents scratches or damages due to harsh cleaning chemicals This warranty does not apply to commercial use or to products with altered or removed serial numbers Twin Eagles shall not be liable for incidental consequential special or contingent damages resulting from its breach of this written warranty or any imp...

Page 19: ... use only Cut Here Or you may fax the form at 562 802 3391 or register online at http www twineaglesbbq com contactus shtml HOW TO OBTAIN SERVICE For service please contact your TWIN EAGLES dealer or call TWIN EAGLES direct at 800 789 2206 or 562 802 3488 or fax 562 802 3391 Mailing address Twin Eagles Inc 13231 East 166th Street Cerritos CA 90703 Visit us at www twineaglesbbq com Please provide M...

Page 20: ...ATTN Warranty Department 13231 East 166th Street Cerritos CA 90703 Fax no 562 802 3391 Place the Postage Here Cut Here 15 ...

Reviews: