1.8 Calibration of lambda probe
If the lambda probe over time becomes less precise, it has to be calibrated.
In normal atmospheric air the oxygen content is always app. 21 % ( O
2
). This can be
used as point of reference for the measurement of the oxygen content. The lambda
probe should be calibrated if the oxygen content in air deviates more than ± 2% from
21%. This can only be established, when the probe is exposed to
absolutely clean
atmospheric air
This is most easily done, when the boiler has been stopped for a period. There should
not be any smoke at all in the combustion room or the flue pipe, when making the test.
Close the bypass damper on top of the boiler and undo the top cleaning door to the flue
pipes, now the chimney will suck in “clean” air, passing by the probe.
The cursor must be placed by the line
Setting
Press
to choose
setting
Press
to
Calibrate O2
Press
: Now you can change
No
to
YES
by pressing
.
Confirm the change with
Now the lambda probe is calibrated (adjusted)
1.9 Reset all
If you want to reset all parameters to factory settings, chose YES
.
Remember to re-calibrate the lambda probe as described above