4
1.2 Menu structure
The various adjustment possibilities are looked up in searching by means of the arrows
at the front of the control panel
If you want to leave the menu without making any changes, press
Errors are cancelled by pressing »START«
*O2 regulator menu*
O2 regulation YES
Man. fac pel. 35%
*Other fuel menu**
START
Soft start 20m
Stoker delay 5m
OPERATION
O2 0% 18%
O2 100% 8,50%
O2 pkt. 30,00%
O2 proc. 5,00%
Stoker puls 1,00s
Stoker term 30s
Factor 35%
PAUSE
Stoker puls 1,00s
Stoker term 600s
After run B. 4
Start puls 6,00s
Temp Setpoint 70C
Fuel type Pel.
Calibrate O2 No
O2 regul. on/off......................
Other fuel...............................
Stokermotor menu.................
: 67,8
: 9,6
: 9,3
: 0,8
Pel. Running 67%
C
%
%
S
Temperature
O2 Auto
O2 Wanted
Stoker puls
Setting....................................
*Stoker Motor menu
Power setpkt 50
Error times 10
Power: 0 Times: 0
**Settings menu***
Fire starter menu
Ash exhale menu
Blaster menu
Password
0
Recall all No
Buffer menu
1.3 Adjustment of temperature
The temperature (boiler temperature) can be adjusted between 70 – 90°C
The temperature is from factory pre-set to 70°C.
Some situations – such as an under-dimensioned radiator system or hot water tank
might make it desirable to adjust the boiler temperature higher than 70 º C
The cursor must be placed by the line
Setting
Press
: The adjusted temperature is shown . (e.g.
70°C
)
Press
: The temperature can be adjusted by pressing
.
Confirm new setting by pressing
Leave the menu by pressing
The water returning to the boiler must always be at
least 60°C
If the above is not respected the corrosion of the steel in the boiler will increase and the
life expectations will be reduced.