www.tsicustomerservice.com
A202
6
TROUBLE SHOOTING
Problem
Root Cause
Corrective Action
No power
Power cord was not
plugged into the outlet.
Check that the unit is plugged into a standard 120V outlet.
Logs Glow, flame effect
does not work.
Spinner Motor.
Check whether Flame Generator drive motor is running . If not call the
customer service.
Flame effect operates, but
heater does not
blow warm air.
Heater not turned on.
Try to trun ON/OFF HEATER button several times to make sure it is in ON
position.
Thermostat is set too
low.
Make sure that the Thermostat knob is set to the max setting.
The heater shut off and
won't come back on.
Manual Reset Triggered
Turn the POWER to “OFF” and unplug the unit from the wall outlet for 5
minutes. After 5 minutes plug the unit back into wall outlet, and operate as
normal. If the problem presist contact customer service.
Power cord gets warm.
Normal operation
Check your heater cord and plug connections. Faulty wall outlet connections or
loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight in
the outlet. Heaters draw more current than small appliances, overheating of the
outlet may occur even if it has not occurred with the use of other appliances.
During use check frequently to determine if your plug outlet or faceplate
is HOT! If so, discontinue use of the heater and have a qualified
electrician check and/or replace the faulty outlet(s).
Remote Control is not
working.
No batteries
Change the remote batteries.
Poor Signal
Operate remote transmitter at a slow measured pace.
Press the remote control buttons with an even motion and gentle pressure.
Repeatedly pressing buttons in rapid succession may cause the transmitter to
malfunction.
Distance
Operate the remote at a distance less than 20 feet from the front of the
appliance; point the remote at the control panel.
Unit continues to run after
reaching set temperature/or
powering off.
Cool down cycle
Normal operation, will continue to run for several minutes before shutting
down. Times will vary based on heating. UNIT WILL BLOW COOL AIR.
Flame effect works but
heater function does not
and the emberbed flashes
when the heater button is
pressed.
The heater is disabled.
With the power on and press and hold the heater button on the control panel
for 10 seconds. once re-enabled the emberbed lights will flash multiple times.