Once all settings are set as required, power down the transmitter and
connect the filter and antenna system. Connect the RF sample from
the coupler post filter to the SMA F-SENSE connector on the rear
panel.
Power-up the transmitter and, via the settings menu, increase the RF
power output to the required power level.
Correct operation is confirmed by a front panel green SYSTEM LED.
Should this turn red, the transmission system may shut down its RF
output and will, in any case, require URGENT attention.
The transmitter is designed for continuous reliable transmission,
however the fans, air vents and air tunnels must be periodically
checked for correct operation and free airflow.
The cooling fans should be replaced after 60,000 hours of cumulative
operation. This life rating is for guidance only and is subject to ideal
environmental operating conditions. Replace any fan that fails or
becomes slow or noisy, immediately. It is recommended that
replacement work must be carried out by the manufacturer or an
approved agent.
Operation