background image

 

 

B2723T15             ///        Transport GX15 

B2723T15M 

 

Revision 1.0

 

 

 

Copyright © TYAN Computer Corporation, 2002-2003. All rights reserved. No 
part of this manual may be reproduced or translated without prior written 
consent from TYAN Computer Corp. 
 
 
All registered and unregistered trademarks and company names contained in 
this manual are property of their respective owners including, but not limited to 
the following. 
 
TYAN, Tiger i7501 S2723, Transport B2723T15, Transport B2723T15M, 
Transport GX15 are trademarks of TYAN Computer Corporation. 
Intel, Xeon and combinations thereof are trademarks of Intel Corporation. 
AMI, AMIBIOS are trademarks of AMI Software Incorporated. 
Microsoft, Windows are trademarks of Microsoft Corporation.. 
QLogic, Zircon, and combinations thereof are trademarks of QLogic 
Corporation. 
IBM, PC, AT, PS/2 are trademarks of IBM Corporation. 
Winbond is a trademark of Winbond Electronics Corporation. 
Portable Document Format (PDF) is a trademark of Adobe Corporation. 
 
 
 
Information contained in this document is furnished by TYAN Computer 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
TYAN assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN products including liability or 
warranties relating to fitness for a particular purpose or merchantability. TYAN 
retains the right to make changes to product descriptions and/or specifications 
at any time, without notice. In no event will TYAN be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 

 
 

 

 

http://www.tyan.com 

 

Summary of Contents for B2723T15

Page 1: ... are trademarks of QLogic Corporation IBM PC AT PS 2 are trademarks of IBM Corporation Winbond is a trademark of Winbond Electronics Corporation Portable Document Format PDF is a trademark of Adobe Corporation Information contained in this document is furnished by TYAN Computer Corporation and has been reviewed for accuracy and reliability prior to printing TYAN assumes no liability whatsoever and...

Page 2: ...apter 3 Installing Into A Cabinet or Telco Rack 3 0 Before you begin 3 1 Installing single system into a 19 cabinet Chapter 4 Server Management Daughter Card SMDC 4 1 Summary 4 2 Features at a glance 4 3 Jumper setting 4 4 Specification 4 5 SMDC Features 4 6 Tyan System Operator TSO summary Appendix Safety Document of system Safety Document of SMDC Page 3 Page 4 Page 4 Page 5 Page 6 Page 7 Page 8 ...

Page 3: ...mpatible for standard US voltage 1 x compatible for standard German voltage 1 x Tiger i7501 S2723 User s Manual 1 x Transport B2723T15 B2723T15M User s Manual 1 x Tiger i7501 S2723 Quick Reference 1 x TYAN driver CD 1 x screw 1x Tyan M3289 SMDC optional item for B2723T15M 1x 50 pin SMDC cable optional item for B2723T15M If any of these items are missing please contact your vendor dealer for replac...

Page 4: ...hreading ready utilizing onboard resources so that a second thread of data can be processed in a single processor Special features of this system include IPMI Server Management PCI X support one 10 100 1000 and one 10 100 Ethernet ports and onboard video Remember to visit TYAN s Website at http www tyan com There you can find information on all of TYAN s products with FAQs distributors list and BI...

Page 5: ...sion 1x PCI X expansion slot on riser card Memory Four 184 pin 2 5 Volt DDR DIMM sockets Supports up to 8GB of Registered DDR RAM Supports only Registered ECC type memory modules Integrated LAN Two RJ 45 LAN Connectors with LEDs One 10 100 One 10 100 1000 Server Management Daughter Card Option Tailored for IPMI highest 1 5 specifications Supports flexible Windows and Linux based Management Solutio...

Page 6: ...Front View Power HDD LEDs Power Reset Switches PS 2 Mouse and Keyboard Double deck USB 1 1 Port Add on PCI Expansion Slot Fast Ethernet w LED VGA Port Serial Port Gigabit Ethernet w LED 6 http www tyan com ...

Page 7: ...1 4 Top View Cooling Fans CPU 2 EPS 12V PSU CPU 1 HDD Riser card Memory Slots SMDC Server Management Daughter Card 7 http www tyan com ...

Page 8: ...fely grounded object to release static charge i e power supply case For the safest conditions Tyan recommends wearing a static safety wrist strap 2 Avoid touching the motherboard components IC chips connectors memory modules and leads 3 Motherboard is pre installed in the system if under any circumstances it is removed from the system place the motherboard on a grounded antistatic surface 4 Inspec...

Page 9: ...2 1 Opening the chassis 2 1 1 Push the top cover toward back 2 1 2 Lift up the top cover and remove it from the chassis 2 1 3 Top cover removed 9 http www tyan com ...

Page 10: ... Slide the HDD into place 2 2 2 Connect the Power cable to HDD 2 2 3 Connect ATA cable to HDD Note ATA cable is pre connected to M B J23 2 2 4 Secure the drive with 4 screws from the bottom of the chassis 10 http www tyan com ...

Page 11: ... that they insert the correct way 2 3 3 Seat the processor firmly into the socket by gently pressing down until the processor sits flush with the socket 2 3 4 Place the socket lever back down until it snaps into place 2 3 5 Your processor is installed 2 3 6 Repeat these steps for any additional processors if you are using more than one processor 2 3 7 Seat heatsinks between brackets pre installed ...

Page 12: ... PCI Card 2 4 1 Loosen the screw and remove PCI slot cover 2 4 2 Plug your PCI PCI X add on card into the PCI socket slot on the riser card 2 4 3 Secure Add on card by tightening the screw from the side 12 http www tyan com ...

Page 13: ...ry slots starting with memory slot B1 B2 or A1 A2 2 5 2 Press down on the memory modules until it locks into place 2 5 3 The B2723T15 B2723T15M requires that memory modules be installed IN PAIRS Please refer to S2723 Tiger i7501 M B User s Manual page 16 18 for exact details 2 5 4 To ensure thermal performance LOW PROFILE memory modules are recommended 13 http www tyan com ...

Page 14: ...2 6 Installing Vent Duct 2 6 1 Attach the vent duct on the CPU area 2 6 2 Place the vent duct on the top of CPU area in between the capacitors as shown in pictures 14 http www tyan com ...

Page 15: ...DE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly For detailed M B jumper settings please refer to S2723 Tiger i7501 M B user s manual In the rare circumstance that you have experienced difficulty you can find help by asking your vendor for assistance If they are not available for assistance please find setup inf...

Page 16: ...ystem to directly attach and secure this rackmount system Should you still prefer to have rails in order to slide the system in and out from the cabinet you may purchase a separate rail kit from Tyan Please contact your local Tyan office for more details Note 1 When installing two systems back to back please choose a 19 cabinet of 1000mm and above in depth b 4 post telco rack open air rack 16 http...

Page 17: ...into a cabinet or telco rack 3 1 1 Place the system between the poles inside the cabinet 3 1 2 Secure the system to the desired location using screws provided by cabinet manufacturer 3 1 3 Finished look 17 http www tyan com ...

Page 18: ...ime Operating System RTOS to complete a variety of tasks Backed by QLogic s reliable ARM7 technology systems are consistently monitored and supported Unlike regular cards such as AGP cards network cards or SCSI cards the SMDC is not a peripheral card that requires any hardware specific driver As long as standby power supports the system the SMDC will monitor the system The Tyan SMDC provides many ...

Page 19: ...Clock IPMI Over LAN Remote sensor monitor host control and system diagnose Remote Host Control Power up down reset power cycle or NMI through LAN port Remote Sensor Monitor SMDC provides sensor information as long as BMC receives enough operating power Remote Diagnostic SMDC allows for system diagnostic when the system is not in operation either intentionally or accidentally through remote IPMI co...

Page 20: ...D Pin 3 SCL J41 HDR4X1 BMC Private I 2 C Pin 4 5VSB 4 4 Specifications The following specifications are described below in detail Hardware Monitoring Protocol and Standard Auxiliary Communication Interface Auxiliary SMBus I 2 C buses Teamed with other IPMB Devices PMCs and EMCs Remote Monitor Control and Diagnostics Sensor Repository System Event Log Field Replaceable Unit Information Storage Emer...

Page 21: ... Auxiliary SMBus I 2 C buses The SMDC provides 4 dedicated and independent buses for user expansion A lot of devices including Northbridge Southbridge Super I O Hardware Monitor LAN controller etc provide I 2 C communication These I2 C buses bridge the proper communication between these devices Teaming with other IPMB Devices PMCs and EMCs Numerous devices in the market already support IPMB commun...

Page 22: ... sensor information including sensor types and measuring units are available on the Intel website regarding IPMI www intel com System Event Log SEL Complete history of system events such as POST events are stored and secured in non volatile memory SEL records critical events when BMC detects a critical event within the server Certain pre programmed actions may take place such as system reboot or s...

Page 23: ...to Serial connector included and a null modem cable not included to hook up to the serial COM port of any PC Use HyperTerminal in Windows to view the EMP console HyperTerminal Settings Terminal Type VT100 or ANSI Baud rate 38400bps Parity N 8 1 Flow control None Real Time Clock RTC SMDC maintains its own RTC for scheduling events and keeps it in sync with system RTC Upgrade firmware The BMC suppor...

Page 24: ... IPMI compliant systems with SMDC It intends to provide IT managers the ability to monitor control and diagnose their Tyan server boards with ease and flexibility in a remote control configuration Consult Tyan System Operator user manual for details OEM Drivers Tyan may provide driver support for other third party software at request Contact your Tyan support representative for more details 24 htt...

Page 25: ...our screen after connecting the necessary components to your SMDC and motherboard Note If the following windows do not appear on your screen press CTRL L to refresh the system When the window titled COM1 Properties appears choose the following settings 1 Select 38400 for Bits per second 2 Select 8 for Data bits 3 Select None for Parity 4 Select 1 for Stop bits 5 Select None for Flow control 6 Pres...

Page 26: ...er Function arrow and ctrl keys act as 2 Select Ctrl H under Backspace key sends 3 Select Auto detect for Emulation 4 Type in ANSI for Telnet terminal ID 5 Select 500 for Backscroll buffer lines 6 Leave the box for Play sound when connecting or disconnecting unchecked 7 Press OK 26 http www tyan com ...

Page 27: ...e ASCII Setup window will then appear 1 Uncheck the Wrap lines that exceed terminal width option 2 Enter 0 in the Line delay and Character delay options EMP continued on the next page 27 http www tyan com ...

Page 28: ...e Keyboard Definitions The table below shows how to navigate in the setup program using the keyboard Key Function Tab Moves from one selection to the next Left Right Arrow Keys Change from one menu to the next Up Down Keys More between selections go to submenu Enter Open highlighted section Esc Go back to previous menu Note Remember to use CTRL L to refresh the terminal screen if there is a displa...

Page 29: ...Note Please open flash exe on the TSO CD and follow the directions on how to flash The file extensions end with mhx and bin 29 http www tyan com ...

Page 30: ... condition of your running system The table below is a key of the possible conditions that your system can be in Status Description Lwer_N_Crtcl Below Lower Non Critical Threshold Lwer_Crtcl Below Lower Critical Threshold Lwer_N_Rcvbl Below Lower Non Recoverable Threshold Uper_N_Crtcl Above Upper Non Critical Threshold Uper_Crtcl Above Upper Critical Threshold Uper_N_Rcvbl Above Upper Non Recovera...

Page 31: ...e Panel System Up Down Power Cycle NMI FRU Browser SDR Browser SEL Browser SNMP Architecture Watchdog Timer Activation Deactivation Remote BIOS Flash Remote BMC Firmware Flash Platform Support Management Console Windows 2000 XP RedHat Linux 7 3 TSO Agent Server Side Windows 2000 RedHat Linux 7 3 31 http www tyan com ...

Page 32: ...et on a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This apparatus complies with the Class B limits for radio interference as specified in the Canadian Department of Communications Radio Interference Regulations Cet appareil est conforme aux norms de Classe B d interference radio tel que specifie par le Min...

Page 33: ...nto an outlet on a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This apparatus complies with the Class B limits for radio interference as specified in the Canadian Department of Communications Radio Interference Regulations Cet appareil est conforme aux norms de Classe B d interference radio tel que specifie...