1.4      Standard Parts List   

 
This section describes TN70E-B7106 package contents and accessories. Open the 
box  carefully  and  ensure  that  all  components  are  present  and  undamaged.  The 
product should arrive with packaged as illustrated below. 

 

1.4.1      Box Contents 

 

If any items are missing or appear damaged, contact your retailer or browse to 
TYAN’s website for service

http://www.tyan.com

 

 

 

(1) 2U chassis 

 

(2) DELTA, DPS 770GB C 770W Power Supply (pre-installed) 

 

(8) 60x38mm Fan (pre-installed) 

 

(1) S7106 Mother Board (pre-installed)   

 

(1) M1701T70-FPB Front Panel Board (pre-installed) 

 

(1) M1702T70-USB USB board (pre-installed) 

 

(1) M1601T70E-D-PDB Power Distribution Board (pre-installed) 

 

(1) M1806G70-FB Fan Board (pre-installed) 

 

(1) M1290T70E-BP12E-12HDD Backplane Board (pre-installed) 

 

(1)

 

M1287G88-BP12-2-1 HDD backplane Board (pre-installed) 

 

(1) M7106-L24-3F riser board (pre-installed) 

 

(1) M7106-R24-3F riser board (pre-installed) 

 

(1) M7106-4E riser board (pre-installed in B7106T70EV8E4HR only) 

 

1.4.2      Accessories   

 

If any items are missing or appear damaged, contact your retailer or browse to 
TYAN’s website for service

http://www.tyan.com

 

 

 

(1) Rail kit 

 

(2) CPU Heatsink 

 

(2) CPU Clip 

 

(2) US power cord 

 

(2) EU power cord 

 

(1) IO PLATE LAN Kit (with gasket)   

 

(1) IO PLATE SFP Kit   

 

(1) 2.5” HDD screw pack 

 

(1) TYAN Quick Installation Guide 

 

(1) TYAN Driver CD 

 

(1) M.2 Screw 

Summary of Contents for B7106T70EV12HR

Page 1: ...TN70E B7106 Service Engineer s Manual ...

Page 2: ...lity or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MITAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information contained ...

Page 3: ...are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Page 4: ...re There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations VCCI A この装置は クラスA情報技術装置です この装置を家庭環境で使用すると電波妨 害を引き起こすことがあります この場合には使用者が適切な対策を講ずるよう要 求されることがあります Safety IEC EN 60950 1 This equipment is compliant ...

Page 5: ...pter provides an introduction to the TYAN TN70E B7106 barebones and standard parts list describes the external components gives an overview of the product from different angles Chapter 2 Setting Up This chapter covers procedures on installing the memory modules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement pro...

Page 6: ... the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and...

Page 7: ...d The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This symbol indicates the presence of a hot surface or hot...

Page 8: ...knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rack by yourself a minimum of two people are needed to move a rack Do not attempt to move a fully loaded rack Remove equipment from the rack before moving it Do not attempt to move a rack on an incline ...

Page 9: ...e equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify that the AC power supply branch circuit that provides power to the rack is not overloaded This will reduce the risk of personal injury fire or damage to the equipme...

Page 10: ...e battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare designated for your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispo...

Page 11: ...e all watches rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service p...

Page 12: ...and Heatsink 32 2 1 3 Installing the PCI E Card 35 2 1 4 Installing the Memory 38 2 1 5 Installing Hard Drives 40 2 2 Rack Mounting 47 2 2 1 Installing the Server in a Rack 47 Chapter 3 Replacing Pre Installed Components 52 3 1 Introduction 52 3 2 Disassembly Flowchart 52 3 3 Removing the Cover 53 3 4 Replacing Motherboard Components 53 3 4 1 Disconnecting All Motherboard Cables 53 3 4 2 Replacing...

Page 13: ...3 9 1 HDD Backplane Board Features 75 3 9 2 Connector Definition 76 3 10 Replacing the Power Distribution Board 77 3 11 Replacing the Rear HDD Backplane Board 78 3 11 1 HDD Backplane Features 79 3 11 2 Connector Definition 80 3 12 Replacing the Power Supply 82 Appendix I Installing IO Plate for OCP Card 84 Appendix I How to recover UEFI BIOS 88 Appendix II PCIE Slot Location and Setup Items Corres...

Page 14: ...14 http www tyan com NOTE ...

Page 15: ... only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the TN70E B7106 in a version that can support up to twelve hot swap 2 5 3 5 SATA HDD SSD or NVMe SSD and two hot swap 2 5 SSD The TN70E B7106 uses TYAN s latest chassis featuring a robust structure and a solid mechanical enclosure All of this provides TN70E B7106 the power ...

Page 16: ... SATA 6Gb s System Cooling Configuration FAN 8 6cm fans Power Supply Type RPSU Input Range AC 100 127V 10A AC 200 240V 5A Frequency 50 60 Hz Output Watts 770 Watts Efficiency 80 plus Platinum Redundancy 1 1 Note The system supports redundant PSU operation if the CPU s TDP equal or less than 165W Processor Socket Type Q ty LGA3647 2 Supported CPU Series Intel Xeon Processor Scalable Families Therma...

Page 17: ...TL8211E Storage SATA Connector 3 Mini SAS HD 12 ports 2 SATA III totally support 14 ports Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 I O Ports USB 2 USB2 0 ports 2 at front 2 USB3 0 ports 2 at rear COM 1 DB 9 COM port VGA 1 D Sub 15 pin port RJ 45 2 GbE ports 1 PHY dedicated for IPMI TPM O...

Page 18: ...le H W monitoring Operating System OS supported list Please refer to our Intel OS supported list Regulation FCC DoC Class A CE DoC Class A VCCI Class A CB LVD Yes RCM Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Manual 1 Quick Installation Gui...

Page 19: ...the CPU s TDP equal or less than 165W Processor Socket Type Q ty LGA3647 2 Supported CPU Series Intel Xeon Processor Scalable Families Thermal Design Power TDP wattage Max up to 205W System Bus Up to 10 4 9 6 GT s with Intel UltraPath Interconnect UPI support Chipset PCH Intel C621 Memory Supported DIMM Qty 8 8 DIMM slots DIMM Type Speed DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 2666 Capacity Up to 5...

Page 20: ...OM port VGA 1 D Sub 15 pin port RJ 45 2 GbE ports 1 PHY dedicated for IPMI TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer supp...

Page 21: ... A CE DoC Class A VCCI Class A CB LVD Yes RCM Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD Barebone 1 TN70E B7106 Barebone NOTE 1 The specifications are subject to change...

Page 22: ...el Board pre installed 1 M1702T70 USB USB board pre installed 1 M1601T70E D PDB Power Distribution Board pre installed 1 M1806G70 FB Fan Board pre installed 1 M1290T70E BP12E 12HDD Backplane Board pre installed 1 M1287G88 BP12 2 1 HDD backplane Board pre installed 1 M7106 L24 3F riser board pre installed 1 M7106 R24 3F riser board pre installed 1 M7106 4E riser board pre installed in B7106T70EV8E4...

Page 23: ...e Product The following views show you the product 1 5 1 System Front View M1701T70 FPB Front Panel Board 1 Power Button with green LED 5 ID Button 2 IPMI LED 6 USB 2 0 Port 3 ID LED 7 USB 2 0 Port 4 RESET Button 8 3 5 2 5 SSD HDD bays ...

Page 24: ...I LED On Amber Fan fail Over temperature Over Voltage PSU fail On Green No failure ID LED On Blue System identified remotely on the server by clicking the Chassis Locate LED key Off Off System not identified HDD LED LED State Color Description Activity LED Solid On Green Drive present no activity Blinking Drive present with activity Status LED Solid On Red HDD Failed Blinking 1Hz Identify Blinking...

Page 25: ...nsion Slots Gen3 x16 via 2 riser cards 6 ID Button ID LED LED State Color Description ID LED On Blue System identified Off Off System not identified NOTE Press the ID button when the system AC Alternating Current is on then the ID LED will light blue if the system is identified Users from remote sites can also activate the ID LED by entering a few commands in IPMI For detailed software support ple...

Page 26: ... LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Right LED 10 Mbps Link Green Off Active Blinking Green Off 100 Mbps Link Green Green Active Blinking Green Green 1000 Mbps Link Green Amber Active Blinking Green Amber No Link Off Off ...

Page 27: ...m 1 5 3 System Top View 1 12 Hot swap 3 5 2 5 HDD trays 2 M1290T70E BP12E 12 HDD Backplane Board 3 8 System fans 4 M1601T70E D PDB Power Distribution Board 5 DELTA DPS 770GB C 770W Power Supply 6 2 Hot swap 2 5 SSD trays ...

Page 28: ...28 http www tyan com 7 Riser Card Bracket M7106 L24 3F M7106 R24 3F pre installed 8 CPU Sockets 9 Memory Slots 10 Expansion Slots ...

Page 29: ... can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad A T30 Security Torx screwdriver Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove...

Page 30: ... any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do...

Page 31: ...l components on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove TN70E B7106 chassis cover 1 Remove the screw on the left side and unscrew the rear top cover on the back side 2 Slide to lift the rear top cover up ...

Page 32: ...3 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink and make sure the gold arrow is located in the correct direction NOTE A new heatsink comes with pre applied thermal grease Once the heatsink has been removed from the processor you need to clean the processor and heatsink using an alcohol solvent Then apply new thermal grease before reinstalling the heats...

Page 33: ...yan com 4 Take out the protection cap 5 Align the heatsink on the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket ...

Page 34: ...34 http www tyan com 6 To secure the heatsink use a T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 ...

Page 35: ...35 http www tyan com 2 1 3 Installing the PCI E Card Follow these instructions to install the PCI E card 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Page 36: ... com 3 Unscrew to remove the dummy brackets 4 Insert the PCI E card into the riser card bracket and screw it firmly Follow the same procedures to insert the card to the other side of the riser card bracket if necessary ...

Page 37: ...37 http www tyan com 5 The same procedure to install the PCIE card to the second riser card 6 Reposition and screw the riser card bracket into the chassis ...

Page 38: ...memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules ...

Page 39: ...39 http www tyan com Memory Population ...

Page 40: ...SDs and two 2 5 hot swap SSDs Installing 3 5 Hot Swap Hard Drives Follow these instructions to install a 3 5 HDD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD tray out ...

Page 41: ...yan com 41 3 Place the 3 5 hard disk drive into the HDD tray and secure the HDD to the HDD tray using 4 screws 4 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Page 42: ...Drives Follow these instructions to install a 2 5 HDD SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD tray out ...

Page 43: ...43 http www tyan com 3 Place the 2 5 HDD SSD into the HDD tray and align the 2 5 HDD SSD with its guide pins 4 Turn over the HDD tray and secure the HDD SSD to the tray using 4 screws ...

Page 44: ...44 http www tyan com 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Page 45: ...ructions to install a 2 5 SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Remove the 4 screws to detach HDD tray bracket 3 Secure one side HDD screws ...

Page 46: ...46 http www tyan com 4 Secure the other side HDD screws 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Page 47: ...rs screw Pack x 1 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN TN70E B7106 into an industry standard 19 rack NOTE Before mounting the TYAN TN70E B7106 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the cha...

Page 48: ...ssis 1 Draw out the inner rail from the rail assembly When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out 2 Align the inner sliding rail on the side of the server and pull towards the arrow to secure the hooks ...

Page 49: ...re the sliding rail to the other side of the server Installing the Outer Rails to the Unit Secure the outer rails to the rack using four M5 screws and four washers A on each side Rack Mounting the Server 1 Draw out the middle rail to the latch position ...

Page 50: ...50 http www tyan com 2 When the inner rails come to a stop pull the tab to release the latch and push the whole system in 3 Secure the mounting ears of the unit to the rack using two M5 x 20L screws C ...

Page 51: ...51 http www tyan com NOTE ...

Page 52: ...the pre installed components including the Motherboard M1713 G24 FPB Front Panel Board M1283G24 BP12E 4 HDD Backplane M1601T70 D PDB Power Distribution board M7106 L24 3F and M7106 R24 3F Riser cards System fan and Power supply unit etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure ...

Page 53: ...ssis cover first Follow Chapter 2 1 1 to remove the cover of the TN70E B7106 3 4 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Disconnecting All Motherboard Cables 1 Disconnect all cables connected to the motherboard ...

Page 54: ... www tyan com 3 4 2 Replacing the Riser Card Follow these instructions to replace the M7106 L24 3F and M7106 R24 3F Riser cards 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Page 55: ...n com 3 Unscrew the M7016 L24 3F riser card to replace with a new one 4 Unscrew the M7016 R24 3F riser card to replace with a new one 5 Follow the steps described earlier in reverse to reinstall the riser card bracket ...

Page 56: ...www tyan com 3 4 3 PCI E Riser Cards Specification M7106 L24 3F Riser Card 3 4 4 Connector Pin Definition M7106 L24 3F Location Definition J1 J2 J3 J4 PCIe X16 SLOT 4P Power Connector PCIe X8 SLOT PCIe X8 SLOT ...

Page 57: ... com M7106 R24 3F Riser Card 3 4 5 Connector Pin Definition M7106 R24 3F Location Definition J1 J2 J3 J4 PCIe X8 SLOT 4Pin Power Connector PCIe X16 SLOT PCIe X8 SLOT J2 PWR1 Pin Signal Pin Signal 1 12V 2 GND 3 GND 4 5V ...

Page 58: ... of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the air duct processor and heatsink if installed 2 Remove nine screws securing the motherboard to the chassis 3 Carefully lift the motherboard from the chassis ...

Page 59: ...ww tyan com 59 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1701T70 FP Front Panel Board 1 Unscrew to release the Front Panel Board cover 2 Remove the Front Panel Board cover ...

Page 60: ...www tyan com 60 3 Unscrew the Front Panel Board to replace a new one 4 Disconnect the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board ...

Page 61: ...B Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning IPMI LED Dual Color Amber Warning Green Normal Push buttons RESET button ID button Power On Off button with Power On Off LED ...

Page 62: ...o failure ID LED On Blue System identified remotely on the server by clicking the Chassis Locate LED key Off Off System not identified J1 FPIO connector Definition Pin Pin Definition PW_LED 1 2 5VSB Key 3 4 ID_LED PW_LED 5 6 ID_LED HD_LED 7 8 LED_FAULT1 HD_LED 9 10 LED_FAULT2 PWR_SW 11 12 LAN_ACT PWR_SW 13 14 LAN_LINK RESET 15 16 SMB_DAT RESET 17 18 SMB_CLK ID_SW 19 20 NC Temp_sensor 21 22 NC NC 2...

Page 63: ...http www tyan com 63 3 6 Replacing the USB Board Follow these instructions to replace the M1702T70 USB Board 1 Unscrew to release the USB front cover 2 Remove the USB front cover ...

Page 64: ...http www tyan com 64 3 Unscrew the USB Board 4 Disconnect the USB Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the USB Board ...

Page 65: ...erboard 2 USB ports 3 6 2 USB Board Connector Pin Definition J2 2x5 pin Connector for FP Connector of Motherboard Pin Definition Description Pin Definition Description 1 VCC_USB USB power 2 VCC_USB USB power 3 USB_P0_N Port1 J1 USB 4 USB_P1_N Port2 J3 USB 5 USB_P0_P Port1 J1 USB 6 USB_P1_P Port2 J3 USB 7 GND1 Ground 8 GND2 Ground 9 NP 10 NC No connect ...

Page 66: ...http www tyan com 66 3 7 Replacing the System Fan Follow these instructions to replace the fan 1 Disconnect the power cable 2 Press the button to take out the fan from the chassis ...

Page 67: ...67 http www tyan com 3 Release the rubber screws from the fan 1 Loose the screws on both sides 2 Push the latch in the direction as the arrow shown to release the fan from the iron holder ...

Page 68: ...68 http www tyan com 3 Remove the iron holder to replace a new fan 4 After replacing a new one put the fan unit back into the cage ...

Page 69: ...www tyan com 3 8 Replacing the Fan Backplane Board Follow these instructions to replace the M1806G70 FB Fan Board in your system 1 Disconnect all the fan power cable 2 Use a screw driver to unscrew the fan cage ...

Page 70: ...http www tyan com 70 3 And lift it up from the chassis 4 Release the 14 screws on the Fan Backplane Board to replace a new one 5 Follow the steps described in reverse order to reinstall the fan cage ...

Page 71: ... Board in details Form Factor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2x10pin Barebone Fan Connector 1 2x2pin Connector for S7086 3 8 2 Fan BP Board LED Definitions FAN Status Green LED Right Red LED Left With Fan On Off Without Fan Off On ...

Page 72: ...on 12V 1 2 GND GND 3 4 5V Barebone Fan Connector J8 Definition Pin Pin Definition FANIN1 1 2 FANIN6 FANIN2 3 4 FANIN7 FANIN3 5 6 FANIN8 FANIN4 7 8 SIO_FANIN1 FANIN5 9 10 SIO_ FANIN2 GND 11 12 Key MB_PWM2 13 14 MB_PWM1 SIO_ FANIN3 15 16 SMBUS_3V3_DATA SIO_ FANIN4 17 18 SMBUS_3V3_CLK VDD_3 3_AUX 19 20 MB_PWM3 ...

Page 73: ...fore detach the HDD backplane please remove all the HDD trays with HDDs otherwise the HDD backplane will be damage when strains at the disassembly 1 Disconnect all cables connected to the M1290T70E BP12E 12 HDD Backplane Remove the fan cage 2 Unscrew the HDD BP Board ...

Page 74: ...HDD Backplane bracket 4 The HDD BP Board bracket is as shown below 5 Unscrew the backplane and replace with a new HDD backplane board 6 Follow the procedures described earlier to reinstall the HDD backplane board bracket into the chassis ...

Page 75: ...n com 3 9 1 HDD Backplane Board Features Front View Rear View Form Factor Dimension 422 4 29 8mm Specifications Overview 2 OCU Link Connector Input 3 Mini SAS HD Connector Input 12 SATA HDD or 8 SATA HDD 4 NVMe Output ...

Page 76: ...7 SATA8_11 NVME01 NVME23 PW1 SATA NVMe Connector SATA NVMe Connector SATA NVMe Connector SATA NVMe Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector Mini SAS HD Connector Mini SAS HD Connector Mini SAS HD Connector OCULink Connector OCULink Connector Power Connector ...

Page 77: ...s to replace the M1601T70 D PDB Power Distribution Board in your system 1 Disconnect all cables connected to the power distribution board 2 Unscrew to take off the power distribution board and replace with a new one 3 Insert the PDB into the chassis following the above procedures in reverse ...

Page 78: ...8 http www tyan com 3 11 Replacing the Rear HDD Backplane Board Follow the instructions to replace the M1287G88 BP12 2 HDD backplane Board 1 Disconnect all cables and unscrew the power distribution board ...

Page 79: ...an com 3 11 1 HDD Backplane Features Front View Rear View PCB Dimensions 93 36 2mm Layer 4 layers Integrated I O 2 SATA Connectors 1 JTAG Jumper J1 1 SGPIO Connector J2 2 7 pin SATA connector 1 4 Pin Power connector ...

Page 80: ...D_5_RUN P8 P9 VDD_5_RUN HD0_PRS_L P10 P11 SAS0_LED GND P12 P13 HD0_V12HD VDD_5_RUN P14 P15 VDD_5_RUN GND S1 GND1 GND GND GND2 HDD1 HDD Connector Definition Pin Pin Definition SAS_TX1 S2 S3 SAS_TX1 GND S4 S5 SAS_RXBN1 SAS_RXBP1 S6 S7 GND SAS0_PRESENT_L S8 S9 NC NC S10 S11 GND NC S12 S13 NC GND S14 P1 NC NC P2 P3 NC GND P4 P5 GND GND P6 P7 HD1_V5 VDD_5_RUN P8 P9 VDD_5_RUN HD1_PRS_L P10 P11 SAS1_LED ...

Page 81: ... SAS_RXBP1 GND 7 J1 JTAG Connector Definition Pin Pin Definition CPLD_JTAG_TCK 1 2 GND CPLD_JTAG_TDO 3 4 VDD_3P3_RUN CPLD_JTAG_TMS 5 6 NC NC 7 8 NC CPLD_JTAG_TDI 9 10 GND J2 SGPIO Connector Definition Pin Pin Definition SMBUS_3V3_CLK 1 2 SAS_SIO_DIN_A SMBUS_3V3_DATA 3 4 SAS_SIO_DOUT_A GND 5 6 SAS_SIO_END_A NC 7 8 SAS_SIO_CLK_A VCC3_AUX 9 10 NC PW1 Power Connector Definition Pin Pin Definition VDD_...

Page 82: ...ower Supply Follow these instructions to replace the power supply module in your system 1 Press the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the chassis ...

Page 83: ...83 http www tyan com NOTE ...

Page 84: ...O Plate for OCP Card Follow these instructions to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7062 I599 2T 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Page 85: ...e semi shearing for the OCP card slot Discharge the metal slug 4 Take out the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN card is installed Break both for a dual port LAN card ...

Page 86: ...86 http www tyan com 5 Insert the IO Plate to the OCP card LAN port 6 Screw the IO Plate to the chassis ...

Page 87: ...87 http www tyan com 7 Insert the LAN card into the OCP slot 8 Secure the LAN card to the chassis ...

Page 88: ...ent shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the motherboard model number Examples 5630 cap 7106 cap 7109 cap etc Please make sure that you are using the correct BIOS Recovery file from Tyan s web site BIOS Recovery Process 1 Place the recovery BIO...

Page 89: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion is signified with the message Flash update completed Press any key to reset the system displayed on screen 8 Remove the USB disk and reboot If your system does not have video output or the POST code ha...

Page 90: ...nds to IOU0 PCIE PORT 1A1B1C1D PStack1 corresponds to IOU1 PCIE PORT 2A2B2C2D PStack2 corresponds to IOU2 PCIE PORT 3A3B3C3D 2U SKU PCIE slot populates riser card BIOS Setup IIO Configuration PCIE PORT PCIE Slot Location Riser Type Reference on UG Socket0 Configuration IOU2 IIO PCIe Br1 3A3B3C 3D E PCIE M7106 L24 3F up Chapter 2 4 Board Parts Jumpers and Connectors and Motherboar d Component s Soc...

Page 91: ...PCIE Slot Location Riser Type Reference on UG Socket0 Configuration IOU2 IIO PCIe Br1 3A3B3C3D E PCIE M7106 L16 1F chapter 2 4 Board Parts Jumpers and Connectors and Motherboard Components Socket1 Configuration IOU1 IIO PCIe Br2 2A2B2C2D D PCIE M7106 R16 1F PCIe x16 FH HL cards In Left and Right 1U riser cards M7106 L16 1F Sold separately M7106 R16 1F Sold separately ...

Page 92: ...d to S7106MB Cable HDD BP M1290T70E BP12E 12 Connect to S7106MB OCuLink NVME 01 M7106 4E SSATA 2 3 OCuLink NVME 23 M7106 4E SSATA 0 1 Mini SAS HD SATA 4 7 SATA 0 3 Mini SAS HD SATA 8 11 SATA 4 7 2 System FAN Ctrlcable FAN M1806G70 FB Connect to S7106MB J8 FAN_HD1 3 Front Panel Control Cable Front Panel M1701T70 FPB Connect to S7106 MB J1 FPIO_1 4 Front Panel USB Cable Front Panel M1702T70 USB Conn...

Page 93: ...BP12E 12 HDD BP PATX6 7 HDD BP1 2 HDD BP1 PW1 8 Power Supply Cables M1601T70 D PDB Connect to M1287G88 BP12 2 1 Rear HDD BP J3 DVD PW1 9 SATA HDD Cable S7106 MB Connect to M1287G88 BP12 2 1 Rear HDD BP SSATA0 SSATA0 SSATA1 SSATA1 10 SGPIO Cable S7106 MB Connect to M1287G88 BP12 2 1 Rear HDD BP SSATA_SGPIO1 J2 11 Control Internal cable S7106 MB Connect to Chassis J121 Chassis ...

Page 94: ...planation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor SYS_Air_Outlet RT3 and MB_Air_Inlet RT2 They detect the system temperature around NOTE The system temperature is measured in a scale defined by Intel not in Fahrenheit or Ce...

Page 95: ...95 http www tyan com BIOS Temp Sensor Name Explanation ...

Page 96: ...96 http www tyan com ...

Page 97: ..._C_MAX The highest temperature of CPU0 DIMM channel C slot P0_DIMM_CH_D_MAX The highest temperature of CPU0 DIMM channel D slot P0_DIMM_CH_E_MAX The highest temperature of CPU0 DIMM channel E slot P0_DIMM_CH_F_MAX The highest temperature of CPU0 DIMM channel F slot P1_DIMM_CH_A_MAX The highest temperature of CPU1 DIMM channel A slot P1_DIMM_CH_B_MAX The highest temperature of CPU1 DIMM channel B s...

Page 98: ...98 http www tyan com SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12 ...

Page 99: ...0006 M7106 L24 3F PCIEx24 Riser card FRU RC 0500 5411T5640007 M7106 R24 3F PCIEx24 Riser card HDD BP FRU RC 0700 5411T5640016 HDD backplane FRU M1290T70E BP12E 12 for TN70E B7106 Single Box RoHS Rack Mounting CRAL 0170 340786900010 SLIDE RAIL MIC ASSY Cable FRU CS 0330 332810000514 TF POWER CORD SBU US 125 V 16 AWG 1 31mm 1800mm AC PWR CORD CCBL 0300 332810000281 TF PWR CORD EU 250V H05VV FX3C 10A...

Page 100: ...ces such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems running as powerful and productive as possible MITAC also ranks high for its commit...

Page 101: ...roper maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay t...

Reviews: