62
3.5.2 FPB LED and Connector Pin Definition
LED
State
Color
Description
Power
On/Off LED
On
Green
System is turned on
Blinking
Green
System is under S1 or S3 state
Off
Off
Power off
Warning
(IPMI) LED
On
Amber
Fan fail / Over temperature / Over
Voltage / PSU fail
On
Green
No failure
ID LED
On
Blue
System identified remotely on the
server, by clicking the Chassis
Locate LED key.*
Off
Off
System not identified
J1: FPIO connector
Definition
Pin
Pin
Definition
1
2
+5VSB
Key
3
4
PW_LED-
5
6
ID_LED-
7
8
LED_FAULT1-
HD_LED-
9
10
LED_FAULT2-
11
12
LAN_ACT
PWR_SW-
13
14
LAN_LINK#
RESET+
15
16
SMB_DAT
RESET-
17
18
SMB_CLK
ID_SW-
19
20
NC
Temp_sensor
21
22
NC
NC
23
24
NC
SMB_ALR
25
26
FPB_HDD_ACTIVITY_G-
SMB_CLK
27
28
FPB_HDD_FAULT_R-
SMB_DAT
29
30
GND