8
4.1.9
Central core ribbon cable.
Prepare the cable. Make sure you have 1,5 m of ribbon fiber on the
tray. Respect dimensions shown on the drawings. Clean the fibers very
well to make easy feeding possible.
4.1.13 If extra split-out is needed the tube divider FIST-GPS2-TD-5MM
can be mounted in the shelf. Assemble the tube divider as shown.
Remove the Velcro strip from the shelf and mount it on the cover.
4.1.10 Mount the cable bracket with 2 screws on the mounting
bracket and place the breakout device on the cable bracket.
4.1.11 Loosen the screw of the strength member stop. Rotate the
stop and position the strength members inside.
4.1.12 Secure with the cable clamp. Don’t squeeze the cable.