8
5.1.2 When all adapters are installed slide them to the left side of the
patch panel, measure the length of the Anti Movement Strip and cut
the AMS to length (distance of the opening minus 6 slots).
5.1.5 Remove the pigtail gland seal and nut , feed the jumper
connectors through the gland and mount the connectors to the
adapter on the patch panel.
5.2
Installation of pigtails with Kevlar termination unit
(KTU)
5.1.3 Install the anti movement strip (AMS) on both the slot sides of
the patch panel.
5.1.4 Mount the pigtail connectors in the adapters and route the
pigtails to the splicing trays.
5.2.1 A Kevlar termination adapter has to be installed in the patch
panel. Push the adapter from the top in the patch panel, an slide it in
position. Each adapter can contain two KTUs.