9
7.3 Place on the cover on the box base and secure the cover with the
screws.
8
Important steps during installations
•
Make sure that grooves on FAS and wraparound groove plate are
clean.
•
Clean the fibers.
•
Tubes routed up to the tube holder should be routed in such a way
that complete access to the tubes is possible without creating
crossings and without creating distortions on the tubes already
installed in the tube holder.
•
Use correct lengths in the tubeholder.
•
Make sure not to loose ID.
9
Rearrangement
•
Avoid to pull fibers in-between groove plates.
•
Avoid fiber movement between tubeholders and first containment
on the FAS block.
•
If accidentally active fibers are removed from the containment
devices, reposition them carefully.
7.4 In case of a box with lock insert first the four guiding pins in the
box before installing the cover.