D-306042 WK160 

User’s Guide

 

as keyproxs, sirens etc.) will stop beeping during the exit delay. 

Skip exit delay:

 Stop the exit delay immediately. 

X-10

 

(PGM

)

Activate the appliance controlled by the chosen X-10 

unit(s) or the device wired to the PGM output. For more details on 
configuring the X-10/PGM output functions, see the corresponding 
sections of the control panel’s Installer Guide (“OUTPUTS” menu) 
and Us

er Guide (“SCHEDULER” menu). 

 

Option settings: 

Not Used

Status

 (default); 

Stop Beeps

Skip 

exit delay

; and 

X-10

 

(PGM

)

 

* Applicable only to control panels that support the voice option. 

Note: 

X-10/PGM not to be enabled in UL Listed Product.

 

 

Define whether or not to report power failure. 

 

Option settings: 

NOT Connected 

(default) and 

Connected to AC

Note:

 For UL Listed product

, set to “NOT Connected”.

 

2.6 Enrolling Proximity Tags 

You can enroll proximity tags in the WP8010/30 panel either via the WK160 touch screen 
keyprox, as described below, or through the WP8010/30 control panel, as described in the 
corresponding section of the control panel's User or Installer Guide. 
Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding 
User Code is programmed for each enrolled proximity tag (code "0000" is not allowed). For 
example, "T02:Tag <Prox>" must be assigned to User Code 2 and "T14:Tag <Prox>" must 
be assigned to User Code 14. Partition authorization of each proximity tag is identical to that 
of the corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3, 
"T03:Tag <Prox>" will also be set to Partitions 1 and 3.

 

Step 

Action 

LCD Display 

Enter the Installer menu of the control panel and 
go to “

02:ZONES/DEVICES

” 

 

Select "

ADD NEW DEVICE

" Option  

 

 

 

When "

ENROLL NOW

"

 

is displayed, press the 

AWAY key (

) on the WK160. The AWAY 

key and the Present Prox Tag key (

) begin 

to blink 

 

Present the proximity tag to the WK160 within the 
timeout period. If the enrollment is successful the 
display reads 

"

DEVICE ENROLLED

"

 and then 

shows the device details 

 

 

AC POWER Connect 

02.ZONES/DEVICES 

 

MODIFY 
DEVICES 

 

ADD NEW 
DEVICES 

 

ENROLL NOW 
or 

T01:Tag (Prox) 

 

DEVICE 
ENROLLED 

 

Summary of Contents for DSC WK160

Page 1: ...ng Options 4 2 4 Enrolling the WK160 6 2 5 Configuring the WK160 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE TOUCH SCREEN KEYPROX 9 3 1 Arming and Disarming the System 9 3 2 Initiating Ala...

Page 2: ...e WK160 can be wall mounted using the supplied bracket or be used as a portable unit For compliance with various international standards the WK160 is equipped with two tamper switches that can be defi...

Page 3: ...incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery polarity 2 2 Closing Battery C...

Page 4: ...Mounting part b A Tamper B DC Power Connection 2 3 Wall Mounting Options The WK160 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 moun...

Page 5: ...Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to the bracke...

Page 6: ...ready enrolled you can configure the WK160 parameters via the Modify Devices option see Step 2 2 5 Configuring the WK160 Parameters Enter the main menu in the WP8010 30 control panel choose the number...

Page 7: ...Note For UL Listed product set to ON Define the volume level of the sounder Option settings Medium default Maximum and Minimum Note For UL Listed product the sounder cannot be used as the only annunci...

Page 8: ...h the WP8010 30 control panel as described in the corresponding section of the control panel s User or Installer Guide Each proximity tag corresponds to its User Code Therefore be sure that a correspo...

Page 9: ...enabled 2 sec Optional 4 INSTANT After arming HOME AWAY 5 7 LATCHKEY After arming AWAY 6 7 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control p...

Page 10: ...conds the WK160 sends the command Fire alarm 2 sec See section 3 3 Panic alarm 2 sec See section 3 3 When pressing the Fire and Emergency icons together the WK160 starts beeping After pressing the but...

Page 11: ...on indication is displayed concurrently with the second partition key LED and then the third partition indication is similarly displayed General Indications The Ready Not Ready Alarm Memory Trouble an...

Page 12: ...ion system has an active trouble status that needs to be reviewed and cleared 3 AC failure Communication failure WK160 is out of range of the control panel or did not get an acknowledge signal of a co...

Page 13: ...s that are assigned to a Partition press the desired Partition number followed by the key Upon each press of the key the next zone number assigned to the pressed Partition number appears on the Zone d...

Page 14: ...X 10 output functions see the corresponding sections of the control panel s Installer Guide OUTPUTS menu and User Guide SCHEDULER menu Step X 10 device ON PGM device ON X 10 or PGM device OFF X 10 or...

Page 15: ...Low Battery Threshold 3 8 V Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Note For UL Listed product the ambient temperature is 32...

Page 16: ...operation The antennas used for this product must not be co located or operated in conjunction with any other antenna or transmitter The portable device version complies with FCC and IC RF radiation...

Page 17: ...ge mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment Digital Security Controls DSC warrants that for a period of 12 months from the date...

Page 18: ...18 D 306042 WK160 User s Guide 2016 Tyco International Ltd and its Respective Companies All Rights Reserved Toronto Canada www dsc com Printed in Israel D 306042 Rev 01 02 16...

Reviews: