8
D-306042 WK160
User’s Guide
as keyproxs, sirens etc.) will stop beeping during the exit delay.
Skip exit delay:
Stop the exit delay immediately.
X-10
(PGM
)
:
Activate the appliance controlled by the chosen X-10
unit(s) or the device wired to the PGM output. For more details on
configuring the X-10/PGM output functions, see the corresponding
sections of the control panel’s Installer Guide (“OUTPUTS” menu)
and Us
er Guide (“SCHEDULER” menu).
Option settings:
Not Used
,
Status
(default);
Stop Beeps
,
Skip
exit delay
; and
X-10
(PGM
)
.
* Applicable only to control panels that support the voice option.
Note:
X-10/PGM not to be enabled in UL Listed Product.
Define whether or not to report power failure.
Option settings:
NOT Connected
(default) and
Connected to AC
.
Note:
For UL Listed product
, set to “NOT Connected”.
2.6 Enrolling Proximity Tags
You can enroll proximity tags in the WP8010/30 panel either via the WK160 touch screen
keyprox, as described below, or through the WP8010/30 control panel, as described in the
corresponding section of the control panel's User or Installer Guide.
Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding
User Code is programmed for each enrolled proximity tag (code "0000" is not allowed). For
example, "T02:Tag <Prox>" must be assigned to User Code 2 and "T14:Tag <Prox>" must
be assigned to User Code 14. Partition authorization of each proximity tag is identical to that
of the corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3,
"T03:Tag <Prox>" will also be set to Partitions 1 and 3.
Step
Action
LCD Display
1
Enter the Installer menu of the control panel and
go to “
02:ZONES/DEVICES
”
2
Select "
ADD NEW DEVICE
" Option
3
When "
ENROLL NOW
"
is displayed, press the
AWAY key (
) on the WK160. The AWAY
key and the Present Prox Tag key (
) begin
to blink
4
Present the proximity tag to the WK160 within the
timeout period. If the enrollment is successful the
display reads
"
DEVICE ENROLLED
"
and then
shows the device details
AC POWER Connect
02.ZONES/DEVICES
MODIFY
DEVICES
ADD NEW
DEVICES
ENROLL NOW
or
T01:Tag (Prox)
DEVICE
ENROLLED